150kbpd Crude Desalting & Atmospheric Topping

Product family: Refinery Light-End Distillation.

Flow: Pipeline & VLCC Crude Tankers → Electrostatic 2-Stage Desalt → 360°C Fired Furnace Preheat → 50-Tray Atmospheric Column → Side-Stripper Kero & Diesel → Tank Farm Blend & Custody Lab → Reformer, FCC & Diesel Hydro

Open this map in the free editor

No account needed. Change any value and the indicators update.

Value stream map

Value stream map: 150kbpd Crude Desalting & Atmospheric ToppingSupplier on the left, customer on the right, process steps in between with their cycle time, and a stock triangle with days of stock before each step. Pipeline & VLCC Crude Tankers → Electrostatic 2-Stage Desalt (393 s) → 360°C Fired Furnace Preheat (492 s) → 50-Tray Atmospheric Column (619 s) → Side-Stripper Kero & Diesel (417 s) → Tank Farm Blend & Custody Lab (312 s) → Reformer, FCC & Diesel Hydro.SUPPLIERPipeline & VLCCCrude TankersI1.30 d1Electrostatic2-Stage DesaltC/T 393 sI1.40 d2360°C FiredFurnace PreheatC/T 492 sI2.00 d350-TrayAtmospheric…C/T 619 sI1.10 d4Side-StripperKero & DieselC/T 417 sI0.80 d5Tank Farm Blend &Custody LabC/T 312 sI1.50 dCUSTOMERReformer, FCC &Diesel Hydro140 / batches

Process steps

StepCycle timeChangeoverUptimeYieldBatchStock beforeCapacity per day
1. Electrostatic 2-Stage Desalt393 s20 min96%99.1%210182 (1.30 d)194
2. 360°C Fired Furnace Preheat492 s35 min93%98.4%210196 (1.40 d)148
3. 50-Tray Atmospheric Column619 s45 min84%96.4%140280 (2.00 d)102
4. Side-Stripper Kero & Diesel417 s10 min96%98.8%56154 (1.10 d)181
5. Tank Farm Blend & Custody Lab312 s10 min98%99.5%35112 (0.80 d)246

Key figures

Takt time
579 s
Lead time
8.13 d
Value-added time
2,233 s
Process cycle efficiency (PCE)
0.34%
Rolled throughput yield (RTY)
92.4%
Customer demand per day
140 batches
Line capacity per day
102 batches
Bottleneck
50-Tray Atmospheric Column

Reading the bottleneck

The bottleneck is "50-Tray Atmospheric Column": it can process 102 batches per day against a demand of 140 batches, so it falls short of demand by 26.8%. Once downtime and scrap are counted, its cycle time grows from 619 s to 764 s, against a takt of 579 s. The largest loss at this step is equipment downtime (uptime 84%), about 118 s per unit. Reducing that loss is where the first improvement test belongs.

The figures on this page are illustrative starting values to be replaced with your own measurements. They are not industry benchmarks.

Other scenarios in this family

More scenarios of Oil, Gas, LNG & Refinery Turnarounds: Oil, Gas, LNG & Refinery Turnarounds