2,400-cph LPG Domestic Gas Cylinder Hydro & Fill

Product family: 12.5kg Safety-Valved Cylinders.

Flow: Bulk Propane/Butane Bullets → Valve Check & Automated Wash → 24-Head Electronic Carousel → Sniffer Gas Leak & Tare Check → Tamper Shrink Cap & Seal → 60-Cylinder Cage Pallet Truck → Household & Hospitality Agents

Open this map in the free editor

No account needed. Change any value and the indicators update.

Value stream map

Value stream map: 2,400-cph LPG Domestic Gas Cylinder Hydro & FillSupplier on the left, customer on the right, process steps in between with their cycle time, and a stock triangle with days of stock before each step. Bulk Propane/Butane Bullets → Valve Check & Automated Wash (2.6 s) → 24-Head Electronic Carousel (3.3 s) → Sniffer Gas Leak & Tare Check (4.1 s) → Tamper Shrink Cap & Seal (2.8 s) → 60-Cylinder Cage Pallet Truck (2.1 s) → Household & Hospitality Agents.SUPPLIERBulkPropane/ButaneBulletsI1.30 d1Valve Check &Automated WashC/T 2.6 sI1.40 d224-HeadElectronic…C/T 3.3 sI2.00 d3Sniffer Gas Leak& Tare CheckC/T 4.1 sI1.10 d4Tamper Shrink Cap& SealC/T 2.8 sI0.80 d560-Cylinder CagePallet TruckC/T 2.1 sI1.50 dCUSTOMERHousehold &Hospitality…14,000 / units

Process steps

StepCycle timeChangeoverUptimeYieldBatchStock beforeCapacity per day
1. Valve Check & Automated Wash2.6 s20 min96%99.1%21,00018,200 (1.30 d)19,466
2. 24-Head Electronic Carousel3.3 s35 min93%98.4%21,00019,600 (1.40 d)14,586
3. Sniffer Gas Leak & Tare Check4.1 s45 min84%96.4%14,00028,000 (2.00 d)10,132
4. Tamper Shrink Cap & Seal2.8 s10 min96%98.8%5,60015,400 (1.10 d)17,784
5. 60-Cylinder Cage Pallet Truck2.1 s10 min98%99.5%3,50011,200 (0.80 d)23,960

Key figures

Takt time
3.9 s
Lead time
8.10 d
Value-added time
14.9 s
Process cycle efficiency (PCE)
0.003%
Rolled throughput yield (RTY)
92.4%
Customer demand per day
14,000 units
Line capacity per day
10,132 units
Bottleneck
Sniffer Gas Leak & Tare Check

Reading the bottleneck

The bottleneck is "Sniffer Gas Leak & Tare Check": it can process 10,132 units per day against a demand of 14,000 units, so it falls short of demand by 27.6%. Once downtime and scrap are counted, its cycle time grows from 4.1 s to 5.1 s, against a takt of 3.9 s. The largest loss at this step is equipment downtime (uptime 84%), about 0.8 s per unit. Reducing that loss is where the first improvement test belongs.

The figures on this page are illustrative starting values to be replaced with your own measurements. They are not industry benchmarks.

Other scenarios in this family

More scenarios of Oil, Gas, LNG & Refinery Turnarounds: Oil, Gas, LNG & Refinery Turnarounds