Geothermal Binary Organic Rankine Cycle Plant

Product family: Baseload Heat-to-Power Loop.

Flow: 210°C Deep Brine Wells → Brine Heat-Exchanger Descale → Working Fluid Evaporator Boil → Axial Supersonic ORC Turbine → Air/Water Condenser Loop → Grid Synchronization Load → Baseload Regional Grid

Open this map in the free editor

No account needed. Change any value and the indicators update.

Value stream map

Value stream map: Geothermal Binary Organic Rankine Cycle PlantSupplier on the left, customer on the right, process steps in between with their cycle time, and a stock triangle with days of stock before each step. 210°C Deep Brine Wells → Brine Heat-Exchanger Descale (2,925 s) → Working Fluid Evaporator Boil (3,600 s) → Axial Supersonic ORC Turbine (4,815 s) → Air/Water Condenser Loop (3,330 s) → Grid Synchronization Load (2,340 s) → Baseload Regional Grid.SUPPLIER210°C DeepBrine WellsI1.61 d1BrineHeat-Exchanger…C/T 2,925 sI1.50 d2Working FluidEvaporator BoilC/T 3,600 sI2.22 d3Axial SupersonicORC TurbineC/T 4,815 sI1.00 d4Air/WaterCondenser LoopC/T 3,330 sI0.61 d5GridSynchronization…C/T 2,340 sI0.78 dCUSTOMERBaseloadRegional Grid18 / batches

Process steps

StepCycle timeChangeoverUptimeYieldBatchStock beforeCapacity per day
1. Brine Heat-Exchanger Descale2,925 s20 min94%98.5%1829 (1.61 d)25
2. Working Fluid Evaporator Boil3,600 s25 min91%96.4%1427 (1.50 d)19
3. Axial Supersonic ORC Turbine4,815 s45 min85%92.0%1140 (2.22 d)12
4. Air/Water Condenser Loop3,330 s15 min95%97.5%718 (1.00 d)22
5. Grid Synchronization Load2,340 s8 min97%99.1%411 (0.61 d)32

Key figures

Takt time
4,500 s
Lead time
7.93 d
Value-added time
17,010 s
Process cycle efficiency (PCE)
2.6%
Rolled throughput yield (RTY)
84.4%
Customer demand per day
18 batches
Line capacity per day
12 batches
Bottleneck
Axial Supersonic ORC Turbine

Reading the bottleneck

The bottleneck is "Axial Supersonic ORC Turbine": it can process 12 batches per day against a demand of 18 batches, so it falls short of demand by 30.9%. Once downtime and scrap are counted, its cycle time grows from 4,815 s to 6,157 s, against a takt of 4,500 s. The largest loss at this step is equipment downtime (uptime 85%), about 850 s per unit. Reducing that loss is where the first improvement test belongs.

The figures on this page are illustrative starting values to be replaced with your own measurements. They are not industry benchmarks.