4MWh 20ft Utility BESS Battery Storage Container

Product family: Turnkey Grid-Forming BESS.

Flow: 314Ah LFP Pack Factories → Insulated ISO Shell & Aerosol FSS → Liquid-Cool Floor Manifold Pipe → 12-Rack LFP Module Slide-In → EMS Edge Controller & Fiber → 1500V DC HiPot & Charge Run → Grid Frequency Utilities

Open this map in the free editor

No account needed. Change any value and the indicators update.

Value stream map

Value stream map: 4MWh 20ft Utility BESS Battery Storage ContainerSupplier on the left, customer on the right, process steps in between with their cycle time, and a stock triangle with days of stock before each step. 314Ah LFP Pack Factories → Insulated ISO Shell & Aerosol FSS (4,388 s) → Liquid-Cool Floor Manifold Pipe (5,400 s) → 12-Rack LFP Module Slide-In (7,223 s) → EMS Edge Controller & Fiber (4,995 s) → 1500V DC HiPot & Charge Run (3,510 s) → Grid Frequency Utilities.SUPPLIER314Ah LFP PackFactoriesI1.63 d1Insulated ISOShell & Aerosol…C/T 4,388 sI1.50 d2Liquid-Cool FloorManifold PipeC/T 5,400 sI2.25 d312-Rack LFPModule Slide-InC/T 7,223 sI1.00 d4EMS EdgeController &…C/T 4,995 sI0.63 d51500V DC HiPot &Charge RunC/T 3,510 sI0.75 dCUSTOMERGrid FrequencyUtilities8 / TEU

Process steps

StepCycle timeChangeoverUptimeYieldBatchStock beforeCapacity per day
1. Insulated ISO Shell & Aerosol FSS4,388 s20 min94%98.5%813 (1.63 d)11
2. Liquid-Cool Floor Manifold Pipe5,400 s25 min91%96.4%612 (1.50 d)8
3. 12-Rack LFP Module Slide-In7,223 s45 min85%92.0%518 (2.25 d)5
4. EMS Edge Controller & Fiber4,995 s15 min95%97.5%38 (1.00 d)10
5. 1500V DC HiPot & Charge Run3,510 s8 min97%99.1%25 (0.63 d)14

Key figures

Takt time
6,750 s
Lead time
8.22 d
Value-added time
25,516 s
Process cycle efficiency (PCE)
5.7%
Rolled throughput yield (RTY)
84.4%
Customer demand per day
8 TEU
Line capacity per day
5 TEU
Bottleneck
12-Rack LFP Module Slide-In

Reading the bottleneck

The bottleneck is "12-Rack LFP Module Slide-In": it can process 5 TEU per day against a demand of 8 TEU, so it falls short of demand by 32.8%. Once downtime and scrap are counted, its cycle time grows from 7,223 s to 9,237 s, against a takt of 6,750 s. The largest loss at this step is equipment downtime (uptime 85%), about 1,275 s per unit. Reducing that loss is where the first improvement test belongs.

The figures on this page are illustrative starting values to be replaced with your own measurements. They are not industry benchmarks.