Hot-Fill / Aseptic Sport Isotonic Cap Line

Product family: 500mL Push-Pull Cap Drinks.

Flow: Sport Cap Supplier → Heat-Set Combi Blow-Fill → Ultra-Clean Sports Cap Torque → Stepped Water Cooling Tunnel → Steam Full-Body Shrink Sleeve → Tray Film & High-Bay Pallet → Convenience & Gym Chains

Open this map in the free editor

No account needed. Change any value and the indicators update.

Value stream map

Value stream map: Hot-Fill / Aseptic Sport Isotonic Cap LineSupplier on the left, customer on the right, process steps in between with their cycle time, and a stock triangle with days of stock before each step. Sport Cap Supplier → Heat-Set Combi Blow-Fill (4.4 s) → Ultra-Clean Sports Cap Torque (6.7 s) → Stepped Water Cooling Tunnel (4.9 s) → Steam Full-Body Shrink Sleeve (5.2 s) → Tray Film & High-Bay Pallet (4.1 s) → Convenience & Gym Chains.SUPPLIERSport CapSupplierI1.80 d1Heat-Set CombiBlow-FillC/T 4.4 sI1.50 d2Ultra-CleanSports Cap TorqueC/T 6.7 sI1.40 d3Stepped WaterCooling TunnelC/T 4.9 sI1.20 d4Steam Full-BodyShrink SleeveC/T 5.2 sI0.80 d5Tray Film &High-Bay PalletC/T 4.1 sI1.50 dCUSTOMERConvenience &Gym Chains12,500 / packs

Process steps

StepCycle timeChangeoverUptimeYieldBatchStock beforeCapacity per day
1. Heat-Set Combi Blow-Fill4.4 s45 min92%98.8%15,00022,500 (1.80 d)16,268
2. Ultra-Clean Sports Cap Torque6.7 s65 min84%96.8%15,00018,750 (1.50 d)9,436
3. Stepped Water Cooling Tunnel4.9 s25 min92%98.2%7,50017,500 (1.40 d)14,473
4. Steam Full-Body Shrink Sleeve5.2 s30 min91%98.5%6,25015,000 (1.20 d)13,342
5. Tray Film & High-Bay Pallet4.1 s10 min96%99.5%3,75010,000 (0.80 d)18,405

Key figures

Takt time
6.5 s
Lead time
8.20 d
Value-added time
25.3 s
Process cycle efficiency (PCE)
0.004%
Rolled throughput yield (RTY)
92.0%
Customer demand per day
12,500 packs
Line capacity per day
9,436 packs
Bottleneck
Ultra-Clean Sports Cap Torque

Reading the bottleneck

The bottleneck is "Ultra-Clean Sports Cap Torque": it can process 9,436 packs per day against a demand of 12,500 packs, so it falls short of demand by 24.5%. Once downtime and scrap are counted, its cycle time grows from 6.7 s to 8.2 s, against a takt of 6.5 s. The largest loss at this step is equipment downtime (uptime 84%), about 1.3 s per unit. Reducing that loss is where the first improvement test belongs.

The figures on this page are illustrative starting values to be replaced with your own measurements. They are not industry benchmarks.

Other scenarios in this family

More scenarios of Bottling, Canning & Beverages: Bottling, Canning & Beverages