Outpatient Antibiotic OPAT & Biologic Pump Kit

Product family: Weekly Home IV Elastomeric Pump.

Flow: Elastomeric Balls & Vials → Nursing Lab Creatinine Clear → Sterile Elastomeric Pump Fill → Cold Pack Ancillary Supplies → Pharmacist Tele-Video Check → Next-Day Morning Home Drop → Home Health Nurses

Open this map in the free editor

No account needed. Change any value and the indicators update.

Value stream map

Value stream map: Outpatient Antibiotic OPAT & Biologic Pump KitSupplier on the left, customer on the right, process steps in between with their cycle time, and a stock triangle with days of stock before each step. Elastomeric Balls & Vials → Nursing Lab Creatinine Clear (99.0 s) → Sterile Elastomeric Pump Fill (123 s) → Cold Pack Ancillary Supplies (161 s) → Pharmacist Tele-Video Check (108 s) → Next-Day Morning Home Drop (81.0 s) → Home Health Nurses.SUPPLIERElastomericBalls & VialsI0.80 d1Nursing LabCreatinine ClearC/T 99.0 sI1.10 d2SterileElastomeric Pump…C/T 123 sI1.50 d3Cold PackAncillary…C/T 161 sI0.60 d4PharmacistTele-Video CheckC/T 108 sI0.50 d5Next-Day MorningHome DropC/T 81.0 sI0.50 dCUSTOMERHome HealthNurses180 / packs

Process steps

StepCycle timeChangeoverUptimeYieldBatchStock beforeCapacity per day
1. Nursing Lab Creatinine Clear99.0 s10 min96%97.8%72144 (0.80 d)242
2. Sterile Elastomeric Pump Fill123 s15 min93%98.2%72198 (1.10 d)184
3. Cold Pack Ancillary Supplies161 s25 min85%95.8%90270 (1.50 d)121
4. Pharmacist Tele-Video Check108 s6 min96%99.1%36108 (0.60 d)222
5. Next-Day Morning Home Drop81.0 s5 min98%99.5%3690 (0.50 d)307

Key figures

Takt time
150 s
Lead time
5.02 d
Value-added time
572 s
Process cycle efficiency (PCE)
0.42%
Rolled throughput yield (RTY)
90.7%
Customer demand per day
180 packs
Line capacity per day
121 packs
Bottleneck
Cold Pack Ancillary Supplies

Reading the bottleneck

The bottleneck is "Cold Pack Ancillary Supplies": it can process 121 packs per day against a demand of 180 packs, so it falls short of demand by 32.6%. Once downtime and scrap are counted, its cycle time grows from 161 s to 198 s, against a takt of 150 s. The largest loss at this step is equipment downtime (uptime 85%), about 28.4 s per unit. Reducing that loss is where the first improvement test belongs.

The figures on this page are illustrative starting values to be replaced with your own measurements. They are not industry benchmarks.

Other scenarios in this family

More scenarios of Hospital Pharmacy & CSSD Sterilization: Hospital Pharmacy & CSSD Sterilization