EU-GMP Standardized Medical Cannabis Drying & Dose

Product family: Irradiated Exact-THC Flower.

Flow: Indoor Hydroponic Grow Rooms → Slow 14-Day Dehum Cure Hang → Cryo Trim & Terpene Preserve → Electron-Beam Microbial Kill → HPLC Potency & Mycotoxin QC → Tamper Jar & Pharmacy Track → Licensed Medical Pharmacies

Open this map in the free editor

No account needed. Change any value and the indicators update.

Value stream map

Value stream map: EU-GMP Standardized Medical Cannabis Drying & DoseSupplier on the left, customer on the right, process steps in between with their cycle time, and a stock triangle with days of stock before each step. Indoor Hydroponic Grow Rooms → Slow 14-Day Dehum Cure Hang (7.4 s) → Cryo Trim & Terpene Preserve (9.2 s) → Electron-Beam Microbial Kill (12.0 s) → HPLC Potency & Mycotoxin QC (8.1 s) → Tamper Jar & Pharmacy Track (6.1 s) → Licensed Medical Pharmacies.SUPPLIERIndoorHydroponic GrowRoomsI0.80 d1Slow 14-Day DehumCure HangC/T 7.4 sI1.10 d2Cryo Trim &Terpene PreserveC/T 9.2 sI1.50 d3Electron-BeamMicrobial KillC/T 12.0 sI0.60 d4HPLC Potency &Mycotoxin QCC/T 8.1 sI0.50 d5Tamper Jar &Pharmacy TrackC/T 6.1 sI0.50 dCUSTOMERLicensedMedical…4,800 / packs

Process steps

StepCycle timeChangeoverUptimeYieldBatchStock beforeCapacity per day
1. Slow 14-Day Dehum Cure Hang7.4 s10 min96%97.8%1,9203,840 (0.80 d)6,661
2. Cryo Trim & Terpene Preserve9.2 s15 min93%98.2%1,9205,280 (1.10 d)5,137
3. Electron-Beam Microbial Kill12.0 s25 min85%95.8%2,4007,200 (1.50 d)3,461
4. HPLC Potency & Mycotoxin QC8.1 s6 min96%99.1%9602,880 (0.60 d)6,131
5. Tamper Jar & Pharmacy Track6.1 s5 min98%99.5%9602,400 (0.50 d)8,392

Key figures

Takt time
11.3 s
Lead time
5.00 d
Value-added time
42.8 s
Process cycle efficiency (PCE)
0.016%
Rolled throughput yield (RTY)
90.7%
Customer demand per day
4,800 packs
Line capacity per day
3,461 packs
Bottleneck
Electron-Beam Microbial Kill

Reading the bottleneck

The bottleneck is "Electron-Beam Microbial Kill": it can process 3,461 packs per day against a demand of 4,800 packs, so it falls short of demand by 27.9%. Once downtime and scrap are counted, its cycle time grows from 12.0 s to 14.7 s, against a takt of 11.3 s. The largest loss at this step is equipment downtime (uptime 85%), about 2.1 s per unit. Reducing that loss is where the first improvement test belongs.

The figures on this page are illustrative starting values to be replaced with your own measurements. They are not industry benchmarks.

Other scenarios in this family

More scenarios of Hospital Pharmacy & CSSD Sterilization: Hospital Pharmacy & CSSD Sterilization