Veterinary Flavor-Chew & Equine Rx Compounding

Product family: Custom Species-Specific Meds.

Flow: USP Bulk Actives & Flavor → Vet Prescription Dose Verify → Homogenizer Mold Chew Batch → Precision Weight Split Caps → Pet Species Safety Double-Check → Direct Clinic/Home Parcel → Veterinary Clinics & Owners

Open this map in the free editor

No account needed. Change any value and the indicators update.

Value stream map

Value stream map: Veterinary Flavor-Chew & Equine Rx CompoundingSupplier on the left, customer on the right, process steps in between with their cycle time, and a stock triangle with days of stock before each step. USP Bulk Actives & Flavor → Vet Prescription Dose Verify (39.6 s) → Homogenizer Mold Chew Batch (49.0 s) → Precision Weight Split Caps (64.0 s) → Pet Species Safety Double-Check (43.0 s) → Direct Clinic/Home Parcel (32.4 s) → Veterinary Clinics & Owners.SUPPLIERUSP BulkActives &FlavorI0.80 d1Vet PrescriptionDose VerifyC/T 39.6 sI1.10 d2Homogenizer MoldChew BatchC/T 49.0 sI1.50 d3Precision WeightSplit CapsC/T 64.0 sI0.60 d4Pet SpeciesSafety…C/T 43.0 sI0.50 d5DirectClinic/Home…C/T 32.4 sI0.50 dCUSTOMERVeterinaryClinics &…450 / orders

Process steps

StepCycle timeChangeoverUptimeYieldBatchStock beforeCapacity per day
1. Vet Prescription Dose Verify39.6 s10 min96%97.8%180360 (0.80 d)605
2. Homogenizer Mold Chew Batch49.0 s15 min93%98.2%180495 (1.10 d)461
3. Precision Weight Split Caps64.0 s25 min85%95.8%225675 (1.50 d)305
4. Pet Species Safety Double-Check43.0 s6 min96%99.1%90270 (0.60 d)558
5. Direct Clinic/Home Parcel32.4 s5 min98%99.5%90225 (0.50 d)767

Key figures

Takt time
60.0 s
Lead time
5.01 d
Value-added time
228 s
Process cycle efficiency (PCE)
0.17%
Rolled throughput yield (RTY)
90.7%
Customer demand per day
450 orders
Line capacity per day
305 orders
Bottleneck
Precision Weight Split Caps

Reading the bottleneck

The bottleneck is "Precision Weight Split Caps": it can process 305 orders per day against a demand of 450 orders, so it falls short of demand by 32.1%. Once downtime and scrap are counted, its cycle time grows from 64.0 s to 78.6 s, against a takt of 60.0 s. The largest loss at this step is equipment downtime (uptime 85%), about 11.3 s per unit. Reducing that loss is where the first improvement test belongs.

The figures on this page are illustrative starting values to be replaced with your own measurements. They are not industry benchmarks.

Other scenarios in this family

More scenarios of Hospital Pharmacy & CSSD Sterilization: Hospital Pharmacy & CSSD Sterilization