PET/SPECT Radiopharmacy Morning Dose Draw Hub

Product family: Tc-99m Timed Patient Syringes.

Flow: Mo-99 Generators & Cyclotron → Hot-Cell Moly Generator Elute → Kit Tagging & Radio-TLC QC → Dose Calibrator Decay Draw → Lead Pig Shield & Wipe Test → Timed 6AM Hospital Courier → City Nuclear Imaging Hubs

Open this map in the free editor

No account needed. Change any value and the indicators update.

Value stream map

Value stream map: PET/SPECT Radiopharmacy Morning Dose Draw HubSupplier on the left, customer on the right, process steps in between with their cycle time, and a stock triangle with days of stock before each step. Mo-99 Generators & Cyclotron → Hot-Cell Moly Generator Elute (50.0 s) → Kit Tagging & Radio-TLC QC (61.0 s) → Dose Calibrator Decay Draw (80.0 s) → Lead Pig Shield & Wipe Test (54.0 s) → Timed 6AM Hospital Courier (41.0 s) → City Nuclear Imaging Hubs.SUPPLIERMo-99Generators &CyclotronI0.80 d1Hot-Cell MolyGenerator EluteC/T 50.0 sI1.10 d2Kit Tagging &Radio-TLC QCC/T 61.0 sI1.50 d3Dose CalibratorDecay DrawC/T 80.0 sI0.60 d4Lead Pig Shield &Wipe TestC/T 54.0 sI0.50 d5Timed 6AMHospital CourierC/T 41.0 sI0.50 dCUSTOMERCity NuclearImaging Hubs360 / vials

Process steps

StepCycle timeChangeoverUptimeYieldBatchStock beforeCapacity per day
1. Hot-Cell Moly Generator Elute50.0 s10 min96%97.8%144288 (0.80 d)479
2. Kit Tagging & Radio-TLC QC61.0 s15 min93%98.2%144396 (1.10 d)371
3. Dose Calibrator Decay Draw80.0 s25 min85%95.8%180540 (1.50 d)244
4. Lead Pig Shield & Wipe Test54.0 s6 min96%99.1%72216 (0.60 d)444
5. Timed 6AM Hospital Courier41.0 s5 min98%99.5%72180 (0.50 d)606

Key figures

Takt time
75.0 s
Lead time
5.01 d
Value-added time
286 s
Process cycle efficiency (PCE)
0.21%
Rolled throughput yield (RTY)
90.7%
Customer demand per day
360 vials
Line capacity per day
244 vials
Bottleneck
Dose Calibrator Decay Draw

Reading the bottleneck

The bottleneck is "Dose Calibrator Decay Draw": it can process 244 vials per day against a demand of 360 vials, so it falls short of demand by 32.1%. Once downtime and scrap are counted, its cycle time grows from 80.0 s to 98.2 s, against a takt of 75.0 s. The largest loss at this step is equipment downtime (uptime 85%), about 14.1 s per unit. Reducing that loss is where the first improvement test belongs.

The figures on this page are illustrative starting values to be replaced with your own measurements. They are not industry benchmarks.

Other scenarios in this family

More scenarios of Hospital Pharmacy & CSSD Sterilization: Hospital Pharmacy & CSSD Sterilization