Automated High-Bay Mail-Order Chronic Pharmacy

Product family: 90-Day Chronic Rx Parcels.

Flow: National Wholesale Drugs → E-Script Claim Adjudicate → Robotic Vial Count & Pill Eye → Clinical Pharmacist Screen → Automated Envelope & Cold → Parcel Hub Evening Truck → Home Mail-Order Patients

Open this map in the free editor

No account needed. Change any value and the indicators update.

Value stream map

Value stream map: Automated High-Bay Mail-Order Chronic PharmacySupplier on the left, customer on the right, process steps in between with their cycle time, and a stock triangle with days of stock before each step. National Wholesale Drugs → E-Script Claim Adjudicate (4.2 s) → Robotic Vial Count & Pill Eye (5.2 s) → Clinical Pharmacist Screen (6.8 s) → Automated Envelope & Cold (4.6 s) → Parcel Hub Evening Truck (3.4 s) → Home Mail-Order Patients.SUPPLIERNationalWholesale DrugsI0.80 d1E-Script ClaimAdjudicateC/T 4.2 sI1.10 d2Robotic VialCount & Pill EyeC/T 5.2 sI1.50 d3ClinicalPharmacist ScreenC/T 6.8 sI0.60 d4AutomatedEnvelope & ColdC/T 4.6 sI0.50 d5Parcel HubEvening TruckC/T 3.4 sI0.50 dCUSTOMERHome Mail-OrderPatients8,500 / orders

Process steps

StepCycle timeChangeoverUptimeYieldBatchStock beforeCapacity per day
1. E-Script Claim Adjudicate4.2 s10 min96%97.8%3,4006,800 (0.80 d)11,736
2. Robotic Vial Count & Pill Eye5.2 s15 min93%98.2%3,4009,350 (1.10 d)9,089
3. Clinical Pharmacist Screen6.8 s25 min85%95.8%4,25012,750 (1.50 d)6,107
4. Automated Envelope & Cold4.6 s6 min96%99.1%1,7005,100 (0.60 d)10,796
5. Parcel Hub Evening Truck3.4 s5 min98%99.5%1,7004,250 (0.50 d)15,057

Key figures

Takt time
6.4 s
Lead time
5.00 d
Value-added time
24.2 s
Process cycle efficiency (PCE)
0.009%
Rolled throughput yield (RTY)
90.7%
Customer demand per day
8,500 orders
Line capacity per day
6,107 orders
Bottleneck
Clinical Pharmacist Screen

Reading the bottleneck

The bottleneck is "Clinical Pharmacist Screen": it can process 6,107 orders per day against a demand of 8,500 orders, so it falls short of demand by 28.2%. Once downtime and scrap are counted, its cycle time grows from 6.8 s to 8.4 s, against a takt of 6.4 s. The largest loss at this step is equipment downtime (uptime 85%), about 1.2 s per unit. Reducing that loss is where the first improvement test belongs.

The figures on this page are illustrative starting values to be replaced with your own measurements. They are not industry benchmarks.

Other scenarios in this family

More scenarios of Hospital Pharmacy & CSSD Sterilization: Hospital Pharmacy & CSSD Sterilization