Hospital ISO-5 Oncology IV Chemo Compounding

Product family: Patient-Dosed Cytotoxic Bags.

Flow: Vials, Saline & Closed-System Transfer Devices → Oncologist Dose Verification → Pass-Through Wipe & Stage Kit → Robotic / Pharmacist Iso Mix → Gravimetric +/-2% Barcode Check → Pneumatic Tube / Runner Drop → Day Hospital Infusion Chairs

Open this map in the free editor

No account needed. Change any value and the indicators update.

Value stream map

Value stream map: Hospital ISO-5 Oncology IV Chemo CompoundingSupplier on the left, customer on the right, process steps in between with their cycle time, and a stock triangle with days of stock before each step. Vials, Saline & Closed-System Transfer Devices → Oncologist Dose Verification (127 s) → Pass-Through Wipe & Stage Kit (158 s) → Robotic / Pharmacist Iso Mix (206 s) → Gravimetric +/-2% Barcode Check (139 s) → Pneumatic Tube / Runner Drop (104 s) → Day Hospital Infusion Chairs.SUPPLIERVials, Saline &Closed-SystemTransfer…I0.80 d1Oncologist DoseVerificationC/T 127 sI1.10 d2Pass-Through Wipe& Stage KitC/T 158 sI1.50 d3Robotic /Pharmacist Iso…C/T 206 sI0.60 d4Gravimetric +/-2%Barcode CheckC/T 139 sI0.50 d5Pneumatic Tube /Runner DropC/T 104 sI0.50 dCUSTOMERDay HospitalInfusion Chairs140 / packs

Process steps

StepCycle timeChangeoverUptimeYieldBatchStock beforeCapacity per day
1. Oncologist Dose Verification127 s10 min96%97.8%56112 (0.80 d)189
2. Pass-Through Wipe & Stage Kit158 s15 min93%98.2%56154 (1.10 d)143
3. Robotic / Pharmacist Iso Mix206 s25 min85%95.8%70210 (1.50 d)95
4. Gravimetric +/-2% Barcode Check139 s6 min96%99.1%2884 (0.60 d)172
5. Pneumatic Tube / Runner Drop104 s5 min98%99.5%2870 (0.50 d)239

Key figures

Takt time
193 s
Lead time
5.03 d
Value-added time
734 s
Process cycle efficiency (PCE)
0.54%
Rolled throughput yield (RTY)
90.7%
Customer demand per day
140 packs
Line capacity per day
95 packs
Bottleneck
Robotic / Pharmacist Iso Mix

Reading the bottleneck

The bottleneck is "Robotic / Pharmacist Iso Mix": it can process 95 packs per day against a demand of 140 packs, so it falls short of demand by 32.2%. Once downtime and scrap are counted, its cycle time grows from 206 s to 253 s, against a takt of 193 s. The largest loss at this step is equipment downtime (uptime 85%), about 36.4 s per unit. Reducing that loss is where the first improvement test belongs.

The figures on this page are illustrative starting values to be replaced with your own measurements. They are not industry benchmarks.

Other scenarios in this family

More scenarios of Hospital Pharmacy & CSSD Sterilization: Hospital Pharmacy & CSSD Sterilization