Multi-Chair Dental Clinic Cassette Sterilization

Product family: Class-B Autoclave Loop.

Flow: Operatory Chairside Suites → Chairside Enzymatic Gel Spray → Thermal Disinfector & Oil Lube → Wrapped Color Cassette Seal → Class-B Vacuum Steam Autoclave → Clean Chair Cupboard Restock → 12 Dental Operatories

Open this map in the free editor

No account needed. Change any value and the indicators update.

Value stream map

Value stream map: Multi-Chair Dental Clinic Cassette SterilizationSupplier on the left, customer on the right, process steps in between with their cycle time, and a stock triangle with days of stock before each step. Operatory Chairside Suites → Chairside Enzymatic Gel Spray (188 s) → Thermal Disinfector & Oil Lube (233 s) → Wrapped Color Cassette Seal (304 s) → Class-B Vacuum Steam Autoclave (205 s) → Clean Chair Cupboard Restock (153 s) → 12 Dental Operatories.SUPPLIEROperatoryChairsideSuitesI0.80 d1ChairsideEnzymatic Gel…C/T 188 sI1.11 d2ThermalDisinfector & Oi…C/T 233 sI1.51 d3Wrapped ColorCassette SealC/T 304 sI0.60 d4Class-B VacuumSteam AutoclaveC/T 205 sI0.51 d5Clean ChairCupboard RestockC/T 153 sI0.51 dCUSTOMER12 DentalOperatories95 / crates

Process steps

StepCycle timeChangeoverUptimeYieldBatchStock beforeCapacity per day
1. Chairside Enzymatic Gel Spray188 s10 min96%97.8%3876 (0.80 d)127
2. Thermal Disinfector & Oil Lube233 s15 min93%98.2%38105 (1.11 d)97
3. Wrapped Color Cassette Seal304 s25 min85%95.8%48143 (1.51 d)64
4. Class-B Vacuum Steam Autoclave205 s6 min96%99.1%1957 (0.60 d)117
5. Clean Chair Cupboard Restock153 s5 min98%99.5%1948 (0.51 d)163

Key figures

Takt time
284 s
Lead time
5.06 d
Value-added time
1,083 s
Process cycle efficiency (PCE)
0.79%
Rolled throughput yield (RTY)
90.7%
Customer demand per day
95 crates
Line capacity per day
64 crates
Bottleneck
Wrapped Color Cassette Seal

Reading the bottleneck

The bottleneck is "Wrapped Color Cassette Seal": it can process 64 crates per day against a demand of 95 crates, so it falls short of demand by 32.2%. Once downtime and scrap are counted, its cycle time grows from 304 s to 373 s, against a takt of 284 s. The largest loss at this step is equipment downtime (uptime 85%), about 53.6 s per unit. Reducing that loss is where the first improvement test belongs.

The figures on this page are illustrative starting values to be replaced with your own measurements. They are not industry benchmarks.

Other scenarios in this family

More scenarios of Hospital Pharmacy & CSSD Sterilization: Hospital Pharmacy & CSSD Sterilization