Long-Term Care 7-Day Multi-Med Pouches

Product family: Nursing Home Compliance Strips.

Flow: Bulk Generic Medication → Nursing MAR Med-List Sync → Automated Multi-Pill Roll Fill → Optical Camera Pill-Count QC → Heat-Seal Daily Time Pouches → Tote Delivery Route Lock → Assisted Living Homes

Open this map in the free editor

No account needed. Change any value and the indicators update.

Value stream map

Value stream map: Long-Term Care 7-Day Multi-Med PouchesSupplier on the left, customer on the right, process steps in between with their cycle time, and a stock triangle with days of stock before each step. Bulk Generic Medication → Nursing MAR Med-List Sync (14.9 s) → Automated Multi-Pill Roll Fill (18.4 s) → Optical Camera Pill-Count QC (24.1 s) → Heat-Seal Daily Time Pouches (16.2 s) → Tote Delivery Route Lock (12.2 s) → Assisted Living Homes.SUPPLIERBulk GenericMedicationI0.80 d1Nursing MARMed-List SyncC/T 14.9 sI1.10 d2AutomatedMulti-Pill Roll…C/T 18.4 sI1.50 d3Optical CameraPill-Count QCC/T 24.1 sI0.60 d4Heat-Seal DailyTime PouchesC/T 16.2 sI0.50 d5Tote DeliveryRoute LockC/T 12.2 sI0.50 dCUSTOMERAssisted LivingHomes2,400 / packs

Process steps

StepCycle timeChangeoverUptimeYieldBatchStock beforeCapacity per day
1. Nursing MAR Med-List Sync14.9 s10 min96%97.8%9601,920 (0.80 d)3,308
2. Automated Multi-Pill Roll Fill18.4 s15 min93%98.2%9602,640 (1.10 d)2,569
3. Optical Camera Pill-Count QC24.1 s25 min85%95.8%1,2003,600 (1.50 d)1,723
4. Heat-Seal Daily Time Pouches16.2 s6 min96%99.1%4801,440 (0.60 d)3,065
5. Tote Delivery Route Lock12.2 s5 min98%99.5%4801,200 (0.50 d)4,196

Key figures

Takt time
22.5 s
Lead time
5.00 d
Value-added time
85.8 s
Process cycle efficiency (PCE)
0.032%
Rolled throughput yield (RTY)
90.7%
Customer demand per day
2,400 packs
Line capacity per day
1,723 packs
Bottleneck
Optical Camera Pill-Count QC

Reading the bottleneck

The bottleneck is "Optical Camera Pill-Count QC": it can process 1,723 packs per day against a demand of 2,400 packs, so it falls short of demand by 28.2%. Once downtime and scrap are counted, its cycle time grows from 24.1 s to 29.6 s, against a takt of 22.5 s. The largest loss at this step is equipment downtime (uptime 85%), about 4.3 s per unit. Reducing that loss is where the first improvement test belongs.

The figures on this page are illustrative starting values to be replaced with your own measurements. They are not industry benchmarks.

Other scenarios in this family

More scenarios of Hospital Pharmacy & CSSD Sterilization: Hospital Pharmacy & CSSD Sterilization