IP69K Hygienic Stainless Food Delta Robot

Product family: Washdown Pick-and-Place Arms.

Flow: Carbon Rods & 316L Cast → 316L Base Electropolish → Carbon Arm Ball-Joint Epoxy → Direct-Drive Servo Seal Fit → 2D Vision Belt Sync Calib → 90-Pick/Min Washdown Run → Food & Bakery Pack Lines

Open this map in the free editor

No account needed. Change any value and the indicators update.

Value stream map

Value stream map: IP69K Hygienic Stainless Food Delta RobotSupplier on the left, customer on the right, process steps in between with their cycle time, and a stock triangle with days of stock before each step. Carbon Rods & 316L Cast → 316L Base Electropolish (1,350 s) → Carbon Arm Ball-Joint Epoxy (1,620 s) → Direct-Drive Servo Seal Fit (2,064 s) → 2D Vision Belt Sync Calib (1,466 s) → 90-Pick/Min Washdown Run (1,119 s) → Food & Bakery Pack Lines.SUPPLIERCarbon Rods &316L CastI1.79 d1316L BaseElectropolishC/T 1,350 sI1.50 d2Carbon ArmBall-Joint EpoxyC/T 1,620 sI2.00 d3Direct-DriveServo Seal FitC/T 2,064 sI1.00 d42D Vision BeltSync CalibC/T 1,466 sI0.71 d590-Pick/MinWashdown RunC/T 1,119 sI1.21 dCUSTOMERFood & BakeryPack Lines28 / units

Process steps

StepCycle timeChangeoverUptimeYieldBatchStock beforeCapacity per day
1. 316L Base Electropolish1,350 s25 min94%98.4%2250 (1.79 d)36
2. Carbon Arm Ball-Joint Epoxy1,620 s20 min92%97.2%1142 (1.50 d)28
3. Direct-Drive Servo Seal Fit2,064 s30 min85%94.8%1456 (2.00 d)20
4. 2D Vision Belt Sync Calib1,466 s12 min95%98.0%728 (1.00 d)32
5. 90-Pick/Min Washdown Run1,119 s10 min97%99.1%420 (0.71 d)43

Key figures

Takt time
1,929 s
Lead time
8.36 d
Value-added time
7,619 s
Process cycle efficiency (PCE)
1.7%
Rolled throughput yield (RTY)
88.1%
Customer demand per day
28 units
Line capacity per day
20 units
Bottleneck
Direct-Drive Servo Seal Fit

Reading the bottleneck

The bottleneck is "Direct-Drive Servo Seal Fit": it can process 20 units per day against a demand of 28 units, so it falls short of demand by 29.7%. Once downtime and scrap are counted, its cycle time grows from 2,064 s to 2,561 s, against a takt of 1,929 s. The largest loss at this step is equipment downtime (uptime 85%), about 364 s per unit. Reducing that loss is where the first improvement test belongs.

The figures on this page are illustrative starting values to be replaced with your own measurements. They are not industry benchmarks.

Other scenarios in this family

More scenarios of Robotics, Automation & Additive 3D: Robotics, Automation & Additive 3D