UL-291 Bank ATM High-Security Safe Chest

Product family: CEN-IV Armored Cash Safes.

Flow: Wear-resistant & manganese plate → HD Plasma Armored Cut → Heavy Die Press Corner Bend → Multi-Pass Armored Flux Weld → Composite Cement Fill & Cure → Electronic Lock Bolt & Cert → Retail Banking Hardware

Open this map in the free editor

No account needed. Change any value and the indicators update.

Value stream map

Value stream map: UL-291 Bank ATM High-Security Safe ChestSupplier on the left, customer on the right, process steps in between with their cycle time, and a stock triangle with days of stock before each step. Wear-resistant & manganese plate → HD Plasma Armored Cut (668 s) → Heavy Die Press Corner Bend (707 s) → Multi-Pass Armored Flux Weld (1,060 s) → Composite Cement Fill & Cure (825 s) → Electronic Lock Bolt & Cert (609 s) → Retail Banking Hardware.SUPPLIERWear-resistant& manganeseplateI1.80 d1HD Plasma ArmoredCutC/T 668 sI1.20 d2Heavy Die PressCorner BendC/T 707 sI2.11 d3Multi-PassArmored Flux WeldC/T 1,060 sI1.71 d4Composite CementFill & CureC/T 825 sI0.91 d5Electronic LockBolt & CertC/T 609 sI1.20 dCUSTOMERRetail BankingHardware55 / units

Process steps

StepCycle timeChangeoverUptimeYieldBatchStock beforeCapacity per day
1. HD Plasma Armored Cut668 s20 min94%99.1%8399 (1.80 d)74
2. Heavy Die Press Corner Bend707 s10 min95%98.4%2866 (1.20 d)70
3. Multi-Pass Armored Flux Weld1,060 s55 min84%95.2%44116 (2.11 d)38
4. Composite Cement Fill & Cure825 s35 min90%96.8%6694 (1.71 d)55
5. Electronic Lock Bolt & Cert609 s10 min96%99.0%1750 (0.91 d)81

Key figures

Takt time
982 s
Lead time
9.00 d
Value-added time
3,869 s
Process cycle efficiency (PCE)
0.80%
Rolled throughput yield (RTY)
89.0%
Customer demand per day
55 units
Line capacity per day
38 units
Bottleneck
Multi-Pass Armored Flux Weld

Reading the bottleneck

The bottleneck is "Multi-Pass Armored Flux Weld": it can process 38 units per day against a demand of 55 units, so it falls short of demand by 31.6%. Once downtime and scrap are counted, its cycle time grows from 1,060 s to 1,326 s, against a takt of 982 s. The largest loss at this step is equipment downtime (uptime 84%), about 202 s per unit. Reducing that loss is where the first improvement test belongs.

The figures on this page are illustrative starting values to be replaced with your own measurements. They are not industry benchmarks.

Other scenarios in this family

More scenarios of Sheet Metal, Laser & Powder Coat: Sheet Metal, Laser & Powder Coat