Reusable Foldable Fresh Crate Wash & Loop

Product family: Sanitized Food Pooling Crates.

Flow: Supermarket Backroom Drops → Auto Unfold & Label Scrape → 3-Stage 70°C Hydro Tunnel → ATP Hygiene Luminometer Check → Auto Fold & Stack 120-Pallet → Farm Order Pool Dispatch → Farms & Fresh Packhouses

Open this map in the free editor

No account needed. Change any value and the indicators update.

Value stream map

Value stream map: Reusable Foldable Fresh Crate Wash & LoopSupplier on the left, customer on the right, process steps in between with their cycle time, and a stock triangle with days of stock before each step. Supermarket Backroom Drops → Auto Unfold & Label Scrape (1.3 s) → 3-Stage 70°C Hydro Tunnel (1.5 s) → ATP Hygiene Luminometer Check (2.1 s) → Auto Fold & Stack 120-Pallet (1.4 s) → Farm Order Pool Dispatch (1.2 s) → Farms & Fresh Packhouses.SUPPLIERSupermarketBackroom DropsI1.60 d1Auto Unfold &Label ScrapeC/T 1.3 sI1.80 d23-Stage 70°CHydro TunnelC/T 1.5 sI2.40 d3ATP HygieneLuminometer CheckC/T 2.1 sI0.90 d4Auto Fold & Stack120-PalletC/T 1.4 sI0.80 d5Farm Order PoolDispatchC/T 1.2 sI1.40 dCUSTOMERFarms & FreshPackhouses28,000 / crates

Process steps

StepCycle timeChangeoverUptimeYieldBatchStock beforeCapacity per day
1. Auto Unfold & Label Scrape1.3 s12 min95%98.1%14,00044,800 (1.60 d)37,679
2. 3-Stage 70°C Hydro Tunnel1.5 s15 min92%96.4%11,20050,400 (1.80 d)30,597
3. ATP Hygiene Luminometer Check2.1 s20 min84%92.5%14,00067,200 (2.40 d)19,092
4. Auto Fold & Stack 120-Pallet1.4 s8 min95%98.2%7,00025,200 (0.90 d)34,704
5. Farm Order Pool Dispatch1.2 s8 min97%99.4%7,00022,400 (0.80 d)41,845

Key figures

Takt time
1.9 s
Lead time
8.90 d
Value-added time
7.5 s
Process cycle efficiency (PCE)
0.002%
Rolled throughput yield (RTY)
85.4%
Customer demand per day
28,000 crates
Line capacity per day
19,092 crates
Bottleneck
ATP Hygiene Luminometer Check

Reading the bottleneck

The bottleneck is "ATP Hygiene Luminometer Check": it can process 19,092 crates per day against a demand of 28,000 crates, so it falls short of demand by 31.8%. Once downtime and scrap are counted, its cycle time grows from 2.1 s to 2.7 s, against a takt of 1.9 s. The largest loss at this step is equipment downtime (uptime 84%), about 0.4 s per unit. Reducing that loss is where the first improvement test belongs.

The figures on this page are illustrative starting values to be replaced with your own measurements. They are not industry benchmarks.

Other scenarios in this family

More scenarios of Reverse Logistics & Circular Refurbishment: Reverse Logistics & Circular Refurbishment