Regional Brewery Returnable Bottle Sort & Wash

Product family: Refillable Crated Beer Loops.

Flow: Pubs & Supermarket Reverse → Acoustic Foreign-Bottle Kick → Crate Unpack & Label Soak → 80°C Caustic Spray Tunnel → Camera Rim Chip Scuff Audit → Clean Pallet to Bottling Hall → Craft & Regional Breweries

Open this map in the free editor

No account needed. Change any value and the indicators update.

Value stream map

Value stream map: Regional Brewery Returnable Bottle Sort & WashSupplier on the left, customer on the right, process steps in between with their cycle time, and a stock triangle with days of stock before each step. Pubs & Supermarket Reverse → Acoustic Foreign-Bottle Kick (1.2 s) → Crate Unpack & Label Soak (1.4 s) → 80°C Caustic Spray Tunnel (1.8 s) → Camera Rim Chip Scuff Audit (1.2 s) → Clean Pallet to Bottling Hall (1.2 s) → Craft & Regional Breweries.SUPPLIERPubs &SupermarketReverseI1.60 d1AcousticForeign-Bottle…C/T 1.2 sI1.80 d2Crate Unpack &Label SoakC/T 1.4 sI2.40 d380°C CausticSpray TunnelC/T 1.8 sI0.90 d4Camera Rim ChipScuff AuditC/T 1.2 sI0.80 d5Clean Pallet toBottling HallC/T 1.2 sI1.40 dCUSTOMERCraft &Regional…32,000 / packs

Process steps

StepCycle timeChangeoverUptimeYieldBatchStock beforeCapacity per day
1. Acoustic Foreign-Bottle Kick1.2 s12 min95%98.1%16,00051,200 (1.60 d)40,819
2. Crate Unpack & Label Soak1.4 s15 min92%96.4%12,80057,600 (1.80 d)32,783
3. 80°C Caustic Spray Tunnel1.8 s20 min84%92.5%16,00076,800 (2.40 d)22,274
4. Camera Rim Chip Scuff Audit1.2 s8 min95%98.2%8,00028,800 (0.90 d)40,488
5. Clean Pallet to Bottling Hall1.2 s8 min97%99.4%8,00025,600 (0.80 d)41,845

Key figures

Takt time
1.7 s
Lead time
8.90 d
Value-added time
6.8 s
Process cycle efficiency (PCE)
0.001%
Rolled throughput yield (RTY)
85.4%
Customer demand per day
32,000 packs
Line capacity per day
22,274 packs
Bottleneck
80°C Caustic Spray Tunnel

Reading the bottleneck

The bottleneck is "80°C Caustic Spray Tunnel": it can process 22,274 packs per day against a demand of 32,000 packs, so it falls short of demand by 30.4%. Once downtime and scrap are counted, its cycle time grows from 1.8 s to 2.3 s, against a takt of 1.7 s. The largest loss at this step is equipment downtime (uptime 84%), about 0.3 s per unit. Reducing that loss is where the first improvement test belongs.