Decommissioned Fiberglass Wind Blade Cement Co-Feed

Product family: Zero-Landfill Composite Grind.

Flow: Repowered Wind Farms → Diamond Wire Section Port Cut → Primary Shredder & Metal Sep → Hammer Mill Controlled Fiber → Calorific Value & Ash Assay → Bulk Silo Truck to Cement → Cement Kiln & Panel Makers

Open this map in the free editor

No account needed. Change any value and the indicators update.

Value stream map

Value stream map: Decommissioned Fiberglass Wind Blade Cement Co-FeedSupplier on the left, customer on the right, process steps in between with their cycle time, and a stock triangle with days of stock before each step. Repowered Wind Farms → Diamond Wire Section Port Cut (1,530 s) → Primary Shredder & Metal Sep (1,800 s) → Hammer Mill Controlled Fiber (2,430 s) → Calorific Value & Ash Assay (1,665 s) → Bulk Silo Truck to Cement (1,260 s) → Cement Kiln & Panel Makers.SUPPLIERRepowered WindFarmsI1.58 d1Diamond WireSection Port CutC/T 1,530 sI1.83 d2Primary Shredder& Metal SepC/T 1,800 sI2.42 d3Hammer MillControlled FiberC/T 2,430 sI0.92 d4Calorific Value &Ash AssayC/T 1,665 sI0.83 d5Bulk Silo Truckto CementC/T 1,260 sI1.42 dCUSTOMERCement Kiln &Panel Makers12 / tonnes

Process steps

StepCycle timeChangeoverUptimeYieldBatchStock beforeCapacity per day
1. Diamond Wire Section Port Cut1,530 s12 min95%98.1%619 (1.58 d)16
2. Primary Shredder & Metal Sep1,800 s15 min92%96.4%522 (1.83 d)12
3. Hammer Mill Controlled Fiber2,430 s20 min84%92.5%629 (2.42 d)8
4. Calorific Value & Ash Assay1,665 s8 min95%98.2%311 (0.92 d)14
5. Bulk Silo Truck to Cement1,260 s8 min97%99.4%310 (0.83 d)19

Key figures

Takt time
2,250 s
Lead time
9.32 d
Value-added time
8,685 s
Process cycle efficiency (PCE)
3.5%
Rolled throughput yield (RTY)
85.4%
Customer demand per day
12 tonnes
Line capacity per day
8 tonnes
Bottleneck
Hammer Mill Controlled Fiber

Reading the bottleneck

The bottleneck is "Hammer Mill Controlled Fiber": it can process 8 tonnes per day against a demand of 12 tonnes, so it falls short of demand by 34.5%. Once downtime and scrap are counted, its cycle time grows from 2,430 s to 3,127 s, against a takt of 2,250 s. The largest loss at this step is equipment downtime (uptime 84%), about 463 s per unit. Reducing that loss is where the first improvement test belongs.

The figures on this page are illustrative starting values to be replaced with your own measurements. They are not industry benchmarks.

Other scenarios in this family

More scenarios of Reverse Logistics & Circular Refurbishment: Reverse Logistics & Circular Refurbishment