High-Flux Polysulfone Hollow-Fiber Dialyzer
Product family: Single-Use Hemodialysis Carts.
Flow: Polysulfone Resin Supplier → Poly-Membrane Wet-Spin Bundle → Fiber Bundle Insert & Cut → Centrifugal Polyurethane Pot → Header Cap Ultrasonic Weld → 100% Bubble-Point & EtO/Steam → Dialysis Clinic Chains
No account needed. Change any value and the indicators update.
Value stream map
Process steps
| Step | Cycle time | Changeover | Uptime | Yield | Batch | Stock before | Capacity per day |
|---|---|---|---|---|---|---|---|
| 1. Poly-Membrane Wet-Spin Bundle | 8.3 s | 30 min | 94% | 98.5% | 6,800 | 11,560 (1.70 d) | 8,835 |
| 2. Fiber Bundle Insert & Cut | 9.3 s | 25 min | 92% | 97.8% | 5,440 | 10,200 (1.50 d) | 7,655 |
| 3. Centrifugal Polyurethane Pot | 12.9 s | 20 min | 86% | 94.8% | 3,400 | 12,920 (1.90 d) | 4,968 |
| 4. Header Cap Ultrasonic Weld | 8.6 s | 12 min | 95% | 98.9% | 2,720 | 6,800 (1.00 d) | 8,653 |
| 5. 100% Bubble-Point & EtO/Steam | 9.8 s | 15 min | 92% | 98.4% | 10,200 | 16,320 (2.40 d) | 7,427 |
Key figures
- Takt time
- 11.9 s
- Lead time
- 10.5 d
- Value-added time
- 48.9 s
- Process cycle efficiency (PCE)
- 0.006%
- Rolled throughput yield (RTY)
- 88.9%
- Customer demand per day
- 6,800 units
- Line capacity per day
- 4,968 units
- Bottleneck
- Centrifugal Polyurethane Pot
Reading the bottleneck
The bottleneck is "Centrifugal Polyurethane Pot": it can process 4,968 units per day against a demand of 6,800 units, so it falls short of demand by 26.9%. Once downtime and scrap are counted, its cycle time grows from 12.9 s to 15.8 s, against a takt of 11.9 s. The largest loss at this step is equipment downtime (uptime 86%), about 2.1 s per unit. Reducing that loss is where the first improvement test belongs.
The figures on this page are illustrative starting values to be replaced with your own measurements. They are not industry benchmarks.
Other scenarios in this family
More scenarios of Implantable & Surgical MedTech: Implantable & Surgical MedTech
- CoCr Laser-Cut Drug-Eluting Coronary Stent
- Porous 3D-Printed Titanium Hip Acetabular Cup
- Hermetic MRI-Safe Cardiac Pacemaker Can
- Articulating Powered Endoscopic Linear Stapler
- Tubeless Wearable Micro-Fluidic Patch Pump
- Hydrophobic Acrylic Foldable Cataract IOL
- 16-Channel Flexible 3T MRI RF Receiver Coil
- Rechargeable RIC Digital Hearing Aid Micro-Shell
- Reusable Silicone Pediatric SpO2 Finger Sensor
- Closed-System Vacuum PMMA Bone Cement Mixer
- Steerable Braided 8F Electrophysiology Catheter