Fluorescent Sensor Aerobic Blood Culture Bottle

Product family: Sepsis Microbial Growth Vials.

Flow: Tryptic Soy Broth & CO2 Sensor → pH/CO2 Sensor Polymer Drop → Broth Dissolve & Bottle Fill → CO2/N2 Atmosphere Crimp → Autoclave Terminal Cycle → Fluorescence Base Scan & Box → Hospital Bacteriology Labs

Open this map in the free editor

No account needed. Change any value and the indicators update.

Value stream map

Value stream map: Fluorescent Sensor Aerobic Blood Culture BottleSupplier on the left, customer on the right, process steps in between with their cycle time, and a stock triangle with days of stock before each step. Tryptic Soy Broth & CO2 Sensor → pH/CO2 Sensor Polymer Drop (3.4 s) → Broth Dissolve & Bottle Fill (4.2 s) → CO2/N2 Atmosphere Crimp (5.4 s) → Autoclave Terminal Cycle (3.7 s) → Fluorescence Base Scan & Box (3.0 s) → Hospital Bacteriology Labs.SUPPLIERTryptic SoyBroth & CO2SensorI1.50 d1pH/CO2 SensorPolymer DropC/T 3.4 sI1.40 d2Broth Dissolve &Bottle FillC/T 4.2 sI1.80 d3CO2/N2 AtmosphereCrimpC/T 5.4 sI1.00 d4AutoclaveTerminal CycleC/T 3.7 sI1.20 d5Fluorescence BaseScan & BoxC/T 3.0 sI1.80 dCUSTOMERHospitalBacteriology…16,000 / vials

Process steps

StepCycle timeChangeoverUptimeYieldBatchStock beforeCapacity per day
1. pH/CO2 Sensor Polymer Drop3.4 s35 min94%98.1%16,00024,000 (1.50 d)21,399
2. Broth Dissolve & Bottle Fill4.2 s25 min92%97.4%9,60022,400 (1.40 d)16,748
3. CO2/N2 Atmosphere Crimp5.4 s40 min84%95.2%8,00028,800 (1.80 d)11,284
4. Autoclave Terminal Cycle3.7 s15 min94%98.6%6,40016,000 (1.00 d)19,727
5. Fluorescence Base Scan & Box3.0 s10 min96%99.1%8,00019,200 (1.20 d)25,306

Key figures

Takt time
5.1 s
Lead time
8.70 d
Value-added time
19.7 s
Process cycle efficiency (PCE)
0.003%
Rolled throughput yield (RTY)
88.9%
Customer demand per day
16,000 vials
Line capacity per day
11,284 vials
Bottleneck
CO2/N2 Atmosphere Crimp

Reading the bottleneck

The bottleneck is "CO2/N2 Atmosphere Crimp": it can process 11,284 vials per day against a demand of 16,000 vials, so it falls short of demand by 29.5%. Once downtime and scrap are counted, its cycle time grows from 5.4 s to 6.8 s, against a takt of 5.1 s. The largest loss at this step is equipment downtime (uptime 84%), about 1.0 s per unit. Reducing that loss is where the first improvement test belongs.

The figures on this page are illustrative starting values to be replaced with your own measurements. They are not industry benchmarks.

Other scenarios in this family

More scenarios of In-Vitro Diagnostics (IVD) & Kits: In-Vitro Diagnostics (IVD) & Kits