Flocked Nasopharyngeal Swab & Liquid Amies

Product family: Sterile PCR Transport Tubes.

Flow: Nylon Flock Fibers → Injection Shaft Dip Adhesive → Electrostatic Flock Spray & Cure → Tube Amies Media Fill & Cap → Dual Swab + Tube Flowpack → Gamma Irradiation Release → Diagnostic Specimen Sites

Open this map in the free editor

No account needed. Change any value and the indicators update.

Value stream map

Value stream map: Flocked Nasopharyngeal Swab & Liquid AmiesSupplier on the left, customer on the right, process steps in between with their cycle time, and a stock triangle with days of stock before each step. Nylon Flock Fibers → Injection Shaft Dip Adhesive (1.2 s) → Electrostatic Flock Spray & Cure (1.2 s) → Tube Amies Media Fill & Cap (1.4 s) → Dual Swab + Tube Flowpack (1.2 s) → Gamma Irradiation Release (1.2 s) → Diagnostic Specimen Sites.SUPPLIERNylon FlockFibersI1.50 d1Injection ShaftDip AdhesiveC/T 1.2 sI1.40 d2ElectrostaticFlock Spray &…C/T 1.2 sI1.80 d3Tube Amies MediaFill & CapC/T 1.4 sI1.00 d4Dual Swab + TubeFlowpackC/T 1.2 sI1.20 d5Gamma IrradiationReleaseC/T 1.2 sI1.80 dCUSTOMERDiagnosticSpecimen Sites42,000 / units

Process steps

StepCycle timeChangeoverUptimeYieldBatchStock beforeCapacity per day
1. Injection Shaft Dip Adhesive1.2 s35 min94%98.1%42,00063,000 (1.50 d)39,883
2. Electrostatic Flock Spray & Cure1.2 s25 min92%97.4%25,20058,800 (1.40 d)38,457
3. Tube Amies Media Fill & Cap1.4 s40 min84%95.2%21,00075,600 (1.80 d)28,103
4. Dual Swab + Tube Flowpack1.2 s15 min94%98.6%16,80042,000 (1.00 d)39,970
5. Gamma Irradiation Release1.2 s10 min96%99.1%21,00050,400 (1.20 d)41,860

Key figures

Takt time
1.3 s
Lead time
8.70 d
Value-added time
6.2 s
Process cycle efficiency (PCE)
0.001%
Rolled throughput yield (RTY)
88.9%
Customer demand per day
42,000 units
Line capacity per day
28,103 units
Bottleneck
Tube Amies Media Fill & Cap

Reading the bottleneck

The bottleneck is "Tube Amies Media Fill & Cap": it can process 28,103 units per day against a demand of 42,000 units, so it falls short of demand by 33.1%. Once downtime and scrap are counted, its cycle time grows from 1.4 s to 1.8 s, against a takt of 1.3 s. The largest loss at this step is equipment downtime (uptime 84%), about 0.3 s per unit. Reducing that loss is where the first improvement test belongs.

The figures on this page are illustrative starting values to be replaced with your own measurements. They are not industry benchmarks.

Other scenarios in this family

More scenarios of In-Vitro Diagnostics (IVD) & Kits: In-Vitro Diagnostics (IVD) & Kits