Gold-Electrode Reel-to-Reel Glucose Test Strip

Product family: Enzyme Electrochemical Strips.

Flow: FAD-GDH Enzyme Ink → Rotary Screen Carbon/Au Ink → Laser Ablate Electrode Gap → Enzyme Slot-Die Coat & Dry → Hydrophilic Spacer Laminate → Master Reel Singulation & Vial → Pharmacy Retail Channels

Open this map in the free editor

No account needed. Change any value and the indicators update.

Value stream map

Value stream map: Gold-Electrode Reel-to-Reel Glucose Test StripSupplier on the left, customer on the right, process steps in between with their cycle time, and a stock triangle with days of stock before each step. FAD-GDH Enzyme Ink → Rotary Screen Carbon/Au Ink (1.2 s) → Laser Ablate Electrode Gap (1.2 s) → Enzyme Slot-Die Coat & Dry (1.2 s) → Hydrophilic Spacer Laminate (1.2 s) → Master Reel Singulation & Vial (1.2 s) → Pharmacy Retail Channels.SUPPLIERFAD-GDH EnzymeInkI1.50 d1Rotary ScreenCarbon/Au InkC/T 1.2 sI1.40 d2Laser AblateElectrode GapC/T 1.2 sI1.80 d3Enzyme Slot-DieCoat & DryC/T 1.2 sI1.00 d4HydrophilicSpacer LaminateC/T 1.2 sI1.20 d5Master ReelSingulation &…C/T 1.2 sI1.80 dCUSTOMERPharmacy RetailChannels160,000 / units

Process steps

StepCycle timeChangeoverUptimeYieldBatchStock beforeCapacity per day
1. Rotary Screen Carbon/Au Ink1.2 s35 min94%98.1%160,000240,000 (1.50 d)60,631
2. Laser Ablate Electrode Gap1.2 s25 min92%97.4%96,000224,000 (1.40 d)58,619
3. Enzyme Slot-Die Coat & Dry1.2 s40 min84%95.2%80,000288,000 (1.80 d)50,780
4. Hydrophilic Spacer Laminate1.2 s15 min94%98.6%64,000160,000 (1.00 d)60,824
5. Master Reel Singulation & Vial1.2 s10 min96%99.1%80,000192,000 (1.20 d)63,265

Key figures

Takt time
0.5 s
Lead time
8.70 d
Value-added time
6.0 s
Process cycle efficiency (PCE)
0.001%
Rolled throughput yield (RTY)
88.9%
Customer demand per day
160,000 units
Line capacity per day
50,780 units
Bottleneck
Enzyme Slot-Die Coat & Dry

Reading the bottleneck

The bottleneck is "Enzyme Slot-Die Coat & Dry": it can process 50,780 units per day against a demand of 160,000 units, so it falls short of demand by 68.3%. Once downtime and scrap are counted, its cycle time grows from 1.2 s to 1.5 s, against a takt of 0.5 s. The largest loss at this step is equipment downtime (uptime 84%), about 0.2 s per unit. Reducing that loss is where the first improvement test belongs.

The figures on this page are illustrative starting values to be replaced with your own measurements. They are not industry benchmarks.

Other scenarios in this family

More scenarios of In-Vitro Diagnostics (IVD) & Kits: In-Vitro Diagnostics (IVD) & Kits