Positive-Charged Silane Pathology Glass Slide

Product family: IHC Autostainer Barcoded Slides.

Flow: Low-Iron Glass Supplier → CNC Bevel Edge & Clean Rinse → APES Silane Charge Dip Coat → Ceramic Thermal Tab Print → 100-Slide Cleanroom Vision → Vacuum Desiccant Box Pack → Hospital Pathology Labs

Open this map in the free editor

No account needed. Change any value and the indicators update.

Value stream map

Value stream map: Positive-Charged Silane Pathology Glass SlideSupplier on the left, customer on the right, process steps in between with their cycle time, and a stock triangle with days of stock before each step. Low-Iron Glass Supplier → CNC Bevel Edge & Clean Rinse (1.2 s) → APES Silane Charge Dip Coat (1.2 s) → Ceramic Thermal Tab Print (1.3 s) → 100-Slide Cleanroom Vision (1.2 s) → Vacuum Desiccant Box Pack (1.2 s) → Hospital Pathology Labs.SUPPLIERLow-Iron GlassSupplierI1.50 d1CNC Bevel Edge &Clean RinseC/T 1.2 sI1.40 d2APES SilaneCharge Dip CoatC/T 1.2 sI1.80 d3Ceramic ThermalTab PrintC/T 1.3 sI1.00 d4100-SlideCleanroom VisionC/T 1.2 sI1.20 d5Vacuum DesiccantBox PackC/T 1.2 sI1.80 dCUSTOMERHospitalPathology Labs45,000 / samples

Process steps

StepCycle timeChangeoverUptimeYieldBatchStock beforeCapacity per day
1. CNC Bevel Edge & Clean Rinse1.2 s35 min94%98.1%45,00067,500 (1.50 d)39,883
2. APES Silane Charge Dip Coat1.2 s25 min92%97.4%27,00063,000 (1.40 d)38,457
3. Ceramic Thermal Tab Print1.3 s40 min84%95.2%22,50081,000 (1.80 d)30,265
4. 100-Slide Cleanroom Vision1.2 s15 min94%98.6%18,00045,000 (1.00 d)39,970
5. Vacuum Desiccant Box Pack1.2 s10 min96%99.1%22,50054,000 (1.20 d)41,860

Key figures

Takt time
1.2 s
Lead time
8.70 d
Value-added time
6.1 s
Process cycle efficiency (PCE)
0.001%
Rolled throughput yield (RTY)
88.9%
Customer demand per day
45,000 samples
Line capacity per day
30,265 samples
Bottleneck
Ceramic Thermal Tab Print

Reading the bottleneck

The bottleneck is "Ceramic Thermal Tab Print": it can process 30,265 samples per day against a demand of 45,000 samples, so it falls short of demand by 32.7%. Once downtime and scrap are counted, its cycle time grows from 1.3 s to 1.6 s, against a takt of 1.2 s. The largest loss at this step is equipment downtime (uptime 84%), about 0.2 s per unit. Reducing that loss is where the first improvement test belongs.

The figures on this page are illustrative starting values to be replaced with your own measurements. They are not industry benchmarks.