Newborn Metabolic Screening Filter Paper Card

Product family: FDA-Cleared Dried Blood Cards.

Flow: Cotton Filter Paper Supplier → 903 Paper Humidity Equil → Offset Demographic Track Print → 5-Circle Die & Barcode Match → Absorption Time & pH Lot Audit → Clean Shrink Stack Pack → Maternity Wards & Labs

Open this map in the free editor

No account needed. Change any value and the indicators update.

Value stream map

Value stream map: Newborn Metabolic Screening Filter Paper CardSupplier on the left, customer on the right, process steps in between with their cycle time, and a stock triangle with days of stock before each step. Cotton Filter Paper Supplier → 903 Paper Humidity Equil (1.3 s) → Offset Demographic Track Print (1.6 s) → 5-Circle Die & Barcode Match (2.1 s) → Absorption Time & pH Lot Audit (1.4 s) → Clean Shrink Stack Pack (1.2 s) → Maternity Wards & Labs.SUPPLIERCotton FilterPaper SupplierI1.50 d1903 PaperHumidity EquilC/T 1.3 sI1.40 d2OffsetDemographic Trac…C/T 1.6 sI1.80 d35-Circle Die &Barcode MatchC/T 2.1 sI1.00 d4Absorption Time &pH Lot AuditC/T 1.4 sI1.20 d5Clean ShrinkStack PackC/T 1.2 sI1.80 dCUSTOMERMaternity Wards& Labs28,000 / units

Process steps

StepCycle timeChangeoverUptimeYieldBatchStock beforeCapacity per day
1. 903 Paper Humidity Equil1.3 s35 min94%98.1%28,00042,000 (1.50 d)36,815
2. Offset Demographic Track Print1.6 s25 min92%97.4%16,80039,200 (1.40 d)28,843
3. 5-Circle Die & Barcode Match2.1 s40 min84%95.2%14,00050,400 (1.80 d)18,735
4. Absorption Time & pH Lot Audit1.4 s15 min94%98.6%11,20028,000 (1.00 d)34,260
5. Clean Shrink Stack Pack1.2 s10 min96%99.1%14,00033,600 (1.20 d)41,860

Key figures

Takt time
1.9 s
Lead time
8.70 d
Value-added time
7.6 s
Process cycle efficiency (PCE)
0.002%
Rolled throughput yield (RTY)
88.9%
Customer demand per day
28,000 units
Line capacity per day
18,735 units
Bottleneck
5-Circle Die & Barcode Match

Reading the bottleneck

The bottleneck is "5-Circle Die & Barcode Match": it can process 18,735 units per day against a demand of 28,000 units, so it falls short of demand by 33.1%. Once downtime and scrap are counted, its cycle time grows from 2.1 s to 2.6 s, against a takt of 1.9 s. The largest loss at this step is equipment downtime (uptime 84%), about 0.4 s per unit. Reducing that loss is where the first improvement test belongs.

The figures on this page are illustrative starting values to be replaced with your own measurements. They are not industry benchmarks.