Rapid Antigen / Cardiac Lateral Flow Strip Line

Product family: Nitrocellulose POCT Cassettes.

Flow: Nitrocellulose Membrane Supplier → Precision Conjugate Dispense → 37°C Low-RH Laminate Cure → High-Speed Reel Strip Slit → Cassette Snap & Vision QR → N2 Foil Pouch & QC Panel → Hospital & Retail POCT

Open this map in the free editor

No account needed. Change any value and the indicators update.

Value stream map

Value stream map: Rapid Antigen / Cardiac Lateral Flow Strip LineSupplier on the left, customer on the right, process steps in between with their cycle time, and a stock triangle with days of stock before each step. Nitrocellulose Membrane Supplier → Precision Conjugate Dispense (1.2 s) → 37°C Low-RH Laminate Cure (1.2 s) → High-Speed Reel Strip Slit (1.2 s) → Cassette Snap & Vision QR (1.2 s) → N2 Foil Pouch & QC Panel (1.2 s) → Hospital & Retail POCT.SUPPLIERNitrocelluloseMembraneSupplierI1.50 d1PrecisionConjugate…C/T 1.2 sI1.40 d237°C Low-RHLaminate CureC/T 1.2 sI1.80 d3High-Speed ReelStrip SlitC/T 1.2 sI1.00 d4Cassette Snap &Vision QRC/T 1.2 sI1.20 d5N2 Foil Pouch &QC PanelC/T 1.2 sI1.80 dCUSTOMERHospital &Retail POCT85,000 / units

Process steps

StepCycle timeChangeoverUptimeYieldBatchStock beforeCapacity per day
1. Precision Conjugate Dispense1.2 s35 min94%98.1%85,000127,500 (1.50 d)60,631
2. 37°C Low-RH Laminate Cure1.2 s25 min92%97.4%51,000119,000 (1.40 d)58,619
3. High-Speed Reel Strip Slit1.2 s40 min84%95.2%42,500153,000 (1.80 d)50,780
4. Cassette Snap & Vision QR1.2 s15 min94%98.6%34,00085,000 (1.00 d)60,824
5. N2 Foil Pouch & QC Panel1.2 s10 min96%99.1%42,500102,000 (1.20 d)63,265

Key figures

Takt time
1.0 s
Lead time
8.70 d
Value-added time
6.0 s
Process cycle efficiency (PCE)
0.001%
Rolled throughput yield (RTY)
88.9%
Customer demand per day
85,000 units
Line capacity per day
50,780 units
Bottleneck
High-Speed Reel Strip Slit

Reading the bottleneck

The bottleneck is "High-Speed Reel Strip Slit": it can process 50,780 units per day against a demand of 85,000 units, so it falls short of demand by 40.3%. Once downtime and scrap are counted, its cycle time grows from 1.2 s to 1.5 s, against a takt of 1.0 s. The largest loss at this step is equipment downtime (uptime 84%), about 0.2 s per unit. Reducing that loss is where the first improvement test belongs.

The figures on this page are illustrative starting values to be replaced with your own measurements. They are not industry benchmarks.

Other scenarios in this family

More scenarios of In-Vitro Diagnostics (IVD) & Kits: In-Vitro Diagnostics (IVD) & Kits