Sample-to-Answer Microfluidic qPCR Cartridge

Product family: Closed Molecular Multiplex Pods.

Flow: Freeze-Dried PCR Beads → COC Cleanroom Optical Mold → Lyophilized Bead Pick-Place → Laser Foil Valve Welding → Ultrasound Liquid Blister Fill → Vision Foil Integrity & Box → Hospital Microbiology Labs

Open this map in the free editor

No account needed. Change any value and the indicators update.

Value stream map

Value stream map: Sample-to-Answer Microfluidic qPCR CartridgeSupplier on the left, customer on the right, process steps in between with their cycle time, and a stock triangle with days of stock before each step. Freeze-Dried PCR Beads → COC Cleanroom Optical Mold (3.9 s) → Lyophilized Bead Pick-Place (4.7 s) → Laser Foil Valve Welding (6.2 s) → Ultrasound Liquid Blister Fill (4.3 s) → Vision Foil Integrity & Box (3.5 s) → Hospital Microbiology Labs.SUPPLIERFreeze-DriedPCR BeadsI1.50 d1COC CleanroomOptical MoldC/T 3.9 sI1.40 d2Lyophilized BeadPick-PlaceC/T 4.7 sI1.80 d3Laser Foil ValveWeldingC/T 6.2 sI1.00 d4Ultrasound LiquidBlister FillC/T 4.3 sI1.20 d5Vision FoilIntegrity & BoxC/T 3.5 sI1.80 dCUSTOMERHospitalMicrobiology…14,000 / units

Process steps

StepCycle timeChangeoverUptimeYieldBatchStock beforeCapacity per day
1. COC Cleanroom Optical Mold3.9 s35 min94%98.1%14,00021,000 (1.50 d)18,656
2. Lyophilized Bead Pick-Place4.7 s25 min92%97.4%8,40019,600 (1.40 d)14,966
3. Laser Foil Valve Welding6.2 s40 min84%95.2%7,00025,200 (1.80 d)9,828
4. Ultrasound Liquid Blister Fill4.3 s15 min94%98.6%5,60014,000 (1.00 d)16,974
5. Vision Foil Integrity & Box3.5 s10 min96%99.1%7,00016,800 (1.20 d)21,691

Key figures

Takt time
5.8 s
Lead time
8.70 d
Value-added time
22.6 s
Process cycle efficiency (PCE)
0.003%
Rolled throughput yield (RTY)
88.9%
Customer demand per day
14,000 units
Line capacity per day
9,828 units
Bottleneck
Laser Foil Valve Welding

Reading the bottleneck

The bottleneck is "Laser Foil Valve Welding": it can process 9,828 units per day against a demand of 14,000 units, so it falls short of demand by 29.8%. Once downtime and scrap are counted, its cycle time grows from 6.2 s to 7.8 s, against a takt of 5.8 s. The largest loss at this step is equipment downtime (uptime 84%), about 1.2 s per unit. Reducing that loss is where the first improvement test belongs.

The figures on this page are illustrative starting values to be replaced with your own measurements. They are not industry benchmarks.