Vacuum PET Blood Collection EDTA Tube Line

Product family: Spray-Coated Clot & EDTA Tubes.

Flow: Medical PET & Bromobutyl → 48-Cavity Medical PET Mold → Micro-Mist K2EDTA Spray Dry → Rubber Stopper Vacuum Evac → Color-Coded Tube Cap → Vacuum Draw & Label Serialize → Clinical Blood Labs Worldwide

Open this map in the free editor

No account needed. Change any value and the indicators update.

Value stream map

Value stream map: Vacuum PET Blood Collection EDTA Tube LineSupplier on the left, customer on the right, process steps in between with their cycle time, and a stock triangle with days of stock before each step. Medical PET & Bromobutyl → 48-Cavity Medical PET Mold (1.2 s) → Micro-Mist K2EDTA Spray Dry (1.2 s) → Rubber Stopper Vacuum Evac (1.2 s) → Color-Coded Tube Cap (1.2 s) → Vacuum Draw & Label Serialize (1.2 s) → Clinical Blood Labs Worldwide.SUPPLIERMedical PET &BromobutylI1.50 d148-Cavity MedicalPET MoldC/T 1.2 sI1.40 d2Micro-Mist K2EDTASpray DryC/T 1.2 sI1.80 d3Rubber StopperVacuum EvacC/T 1.2 sI1.00 d4Color-Coded TubeCapC/T 1.2 sI1.20 d5Vacuum Draw &Label SerializeC/T 1.2 sI1.80 dCUSTOMERClinical BloodLabs Worldwide90,000 / samples

Process steps

StepCycle timeChangeoverUptimeYieldBatchStock beforeCapacity per day
1. 48-Cavity Medical PET Mold1.2 s35 min94%98.1%90,000135,000 (1.50 d)60,631
2. Micro-Mist K2EDTA Spray Dry1.2 s25 min92%97.4%54,000126,000 (1.40 d)58,619
3. Rubber Stopper Vacuum Evac1.2 s40 min84%95.2%45,000162,000 (1.80 d)50,780
4. Color-Coded Tube Cap1.2 s15 min94%98.6%36,00090,000 (1.00 d)60,824
5. Vacuum Draw & Label Serialize1.2 s10 min96%99.1%45,000108,000 (1.20 d)63,265

Key figures

Takt time
0.9 s
Lead time
8.70 d
Value-added time
6.0 s
Process cycle efficiency (PCE)
0.001%
Rolled throughput yield (RTY)
88.9%
Customer demand per day
90,000 samples
Line capacity per day
50,780 samples
Bottleneck
Rubber Stopper Vacuum Evac

Reading the bottleneck

The bottleneck is "Rubber Stopper Vacuum Evac": it can process 50,780 samples per day against a demand of 90,000 samples, so it falls short of demand by 43.6%. Once downtime and scrap are counted, its cycle time grows from 1.2 s to 1.5 s, against a takt of 0.9 s. The largest loss at this step is equipment downtime (uptime 84%), about 0.2 s per unit. Reducing that loss is where the first improvement test belongs.

The figures on this page are illustrative starting values to be replaced with your own measurements. They are not industry benchmarks.

Other scenarios in this family

More scenarios of In-Vitro Diagnostics (IVD) & Kits: In-Vitro Diagnostics (IVD) & Kits