CMOS Nano-Well DNA Sequencing Flow Cell

Product family: High-Throughput NGS Flow Cells.

Flow: Glass & Silicon Bio-Chips → CMOS Bio-Wafer Silanization → Microfluidic Glass Etch Bond → Oligo Surface Lawn Grafting → Cold Fluidic Manifold Leak → Fluorescence QC & Cold Foil → Genomic Research Centers

Open this map in the free editor

No account needed. Change any value and the indicators update.

Value stream map

Value stream map: CMOS Nano-Well DNA Sequencing Flow CellSupplier on the left, customer on the right, process steps in between with their cycle time, and a stock triangle with days of stock before each step. Glass & Silicon Bio-Chips → CMOS Bio-Wafer Silanization (56.0 s) → Microfluidic Glass Etch Bond (68.0 s) → Oligo Surface Lawn Grafting (89.0 s) → Cold Fluidic Manifold Leak (61.0 s) → Fluorescence QC & Cold Foil (50.0 s) → Genomic Research Centers.SUPPLIERGlass & SiliconBio-ChipsI1.50 d1CMOS Bio-WaferSilanizationC/T 56.0 sI1.40 d2MicrofluidicGlass Etch BondC/T 68.0 sI1.80 d3Oligo SurfaceLawn GraftingC/T 89.0 sI1.00 d4Cold FluidicManifold LeakC/T 61.0 sI1.20 d5Fluorescence QC &Cold FoilC/T 50.0 sI1.80 dCUSTOMERGenomicResearch…650 / units

Process steps

StepCycle timeChangeoverUptimeYieldBatchStock beforeCapacity per day
1. CMOS Bio-Wafer Silanization56.0 s35 min94%98.1%650975 (1.50 d)855
2. Microfluidic Glass Etch Bond68.0 s25 min92%97.4%390910 (1.40 d)679
3. Oligo Surface Lawn Grafting89.0 s40 min84%95.2%3251,170 (1.80 d)442
4. Cold Fluidic Manifold Leak61.0 s15 min94%98.6%260650 (1.00 d)786
5. Fluorescence QC & Cold Foil50.0 s10 min96%99.1%325780 (1.20 d)1,005

Key figures

Takt time
83.1 s
Lead time
8.71 d
Value-added time
324 s
Process cycle efficiency (PCE)
0.069%
Rolled throughput yield (RTY)
88.9%
Customer demand per day
650 units
Line capacity per day
442 units
Bottleneck
Oligo Surface Lawn Grafting

Reading the bottleneck

The bottleneck is "Oligo Surface Lawn Grafting": it can process 442 units per day against a demand of 650 units, so it falls short of demand by 32.0%. Once downtime and scrap are counted, its cycle time grows from 89.0 s to 111 s, against a takt of 83.1 s. The largest loss at this step is equipment downtime (uptime 84%), about 17.0 s per unit. Reducing that loss is where the first improvement test belongs.

The figures on this page are illustrative starting values to be replaced with your own measurements. They are not industry benchmarks.

Other scenarios in this family