96-Well Streptavidin Pre-Coated ELISA Plate

Product family: Diagnostic Microtiter Plates.

Flow: Virgin High-Bind Polystyrene → Optically Clear Polystyrene Mold → Automated 96-Channel Dispense → BSA Blocking & Vacuum Dry → Foil Bag Desiccant Heat Seal → CV <4% Optical Uniformity → Pharma & Research Labs

Open this map in the free editor

No account needed. Change any value and the indicators update.

Value stream map

Value stream map: 96-Well Streptavidin Pre-Coated ELISA PlateSupplier on the left, customer on the right, process steps in between with their cycle time, and a stock triangle with days of stock before each step. Virgin High-Bind Polystyrene → Optically Clear Polystyrene Mold (4.3 s) → Automated 96-Channel Dispense (5.2 s) → BSA Blocking & Vacuum Dry (6.8 s) → Foil Bag Desiccant Heat Seal (4.7 s) → CV <4% Optical Uniformity (3.8 s) → Pharma & Research Labs.SUPPLIERVirginHigh-BindPolystyreneI1.50 d1Optically ClearPolystyrene MoldC/T 4.3 sI1.40 d2Automated96-Channel…C/T 5.2 sI1.80 d3BSA Blocking &Vacuum DryC/T 6.8 sI1.00 d4Foil BagDesiccant Heat…C/T 4.7 sI1.20 d5CV <4% OpticalUniformityC/T 3.8 sI1.80 dCUSTOMERPharma &Research Labs8,500 / units

Process steps

StepCycle timeChangeoverUptimeYieldBatchStock beforeCapacity per day
1. Optically Clear Polystyrene Mold4.3 s35 min94%98.1%8,50012,750 (1.50 d)11,130
2. Automated 96-Channel Dispense5.2 s25 min92%97.4%5,10011,900 (1.40 d)8,875
3. BSA Blocking & Vacuum Dry6.8 s40 min84%95.2%4,25015,300 (1.80 d)5,786
4. Foil Bag Desiccant Heat Seal4.7 s15 min94%98.6%3,4008,500 (1.00 d)10,205
5. CV <4% Optical Uniformity3.8 s10 min96%99.1%4,25010,200 (1.20 d)13,219

Key figures

Takt time
6.4 s
Lead time
8.70 d
Value-added time
24.8 s
Process cycle efficiency (PCE)
0.005%
Rolled throughput yield (RTY)
88.9%
Customer demand per day
8,500 units
Line capacity per day
5,786 units
Bottleneck
BSA Blocking & Vacuum Dry

Reading the bottleneck

The bottleneck is "BSA Blocking & Vacuum Dry": it can process 5,786 units per day against a demand of 8,500 units, so it falls short of demand by 31.9%. Once downtime and scrap are counted, its cycle time grows from 6.8 s to 8.5 s, against a takt of 6.4 s. The largest loss at this step is equipment downtime (uptime 84%), about 1.3 s per unit. Reducing that loss is where the first improvement test belongs.

The figures on this page are illustrative starting values to be replaced with your own measurements. They are not industry benchmarks.