Enteric Pellet Hard-Gelatin Capsule Filling

Product family: Delayed-Release PPI Capsules.

Flow: Empty-capsule manufacturer → Sugar Sphere Drug Layering → Wurster Enteric Polymer Coat → 120k/hr Dosing Disc Encapsule → Polishing & Checkweigh Sort → HDPE Bottle Desiccant & Cap → Global Pharma Distributors

Open this map in the free editor

No account needed. Change any value and the indicators update.

Value stream map

Value stream map: Enteric Pellet Hard-Gelatin Capsule FillingSupplier on the left, customer on the right, process steps in between with their cycle time, and a stock triangle with days of stock before each step. Empty-capsule manufacturer → Sugar Sphere Drug Layering (1.2 s) → Wurster Enteric Polymer Coat (1.2 s) → 120k/hr Dosing Disc Encapsule (1.2 s) → Polishing & Checkweigh Sort (1.2 s) → HDPE Bottle Desiccant & Cap (1.2 s) → Global Pharma Distributors.SUPPLIEREmpty-capsulemanufacturerI1.60 d1Sugar Sphere DrugLayeringC/T 1.2 sI1.80 d2Wurster EntericPolymer CoatC/T 1.2 sI2.10 d3120k/hr DosingDisc EncapsuleC/T 1.2 sI1.20 d4Polishing &Checkweigh SortC/T 1.2 sI1.40 d5HDPE BottleDesiccant & CapC/T 1.2 sI1.80 dCUSTOMERGlobal PharmaDistributors180,000 / units

Process steps

StepCycle timeChangeoverUptimeYieldBatchStock beforeCapacity per day
1. Sugar Sphere Drug Layering1.2 s45 min94%99.1%270,000288,000 (1.60 d)40,522
2. Wurster Enteric Polymer Coat1.2 s75 min89%97.6%270,000324,000 (1.80 d)36,917
3. 120k/hr Dosing Disc Encapsule1.2 s65 min84%96.1%270,000378,000 (2.10 d)34,577
4. Polishing & Checkweigh Sort1.2 s35 min91%98.2%144,000216,000 (1.20 d)38,258
5. HDPE Bottle Desiccant & Cap1.2 s15 min95%99.4%90,000252,000 (1.40 d)41,077

Key figures

Takt time
0.3 s
Lead time
9.90 d
Value-added time
6.0 s
Process cycle efficiency (PCE)
0.001%
Rolled throughput yield (RTY)
90.7%
Customer demand per day
180,000 units
Line capacity per day
34,577 units
Bottleneck
120k/hr Dosing Disc Encapsule

Reading the bottleneck

The bottleneck is "120k/hr Dosing Disc Encapsule": it can process 34,577 units per day against a demand of 180,000 units, so it falls short of demand by 80.8%. Once downtime and scrap are counted, its cycle time grows from 1.2 s to 1.5 s, against a takt of 0.3 s. The largest loss at this step is equipment downtime (uptime 84%), about 0.2 s per unit. Reducing that loss is where the first improvement test belongs.

The figures on this page are illustrative starting values to be replaced with your own measurements. They are not industry benchmarks.

Other scenarios in this family

More scenarios of Oral Solid Dose, Tablets & Blister: Oral Solid Dose, Tablets & Blister