High-Shear Granulation & Film-Coated Tablet

Product family: Cardiovascular Chronic Tabs.

Flow: Excipient Suppliers → Weigh, Sieve & High-Shear Wet → Fluid-Bed Dry & Mill Blend → 90-Station Rotary Compression → Aqueous Pan Film Coating → Blister, Leaflet & Case Pack → Retail Pharmacy Wholesalers

Open this map in the free editor

No account needed. Change any value and the indicators update.

Value stream map

Value stream map: High-Shear Granulation & Film-Coated TabletSupplier on the left, customer on the right, process steps in between with their cycle time, and a stock triangle with days of stock before each step. Excipient Suppliers → Weigh, Sieve & High-Shear Wet (1.2 s) → Fluid-Bed Dry & Mill Blend (1.2 s) → 90-Station Rotary Compression (1.2 s) → Aqueous Pan Film Coating (1.2 s) → Blister, Leaflet & Case Pack (1.2 s) → Retail Pharmacy Wholesalers.SUPPLIERExcipientSuppliersI1.60 d1Weigh, Sieve &High-Shear WetC/T 1.2 sI1.80 d2Fluid-Bed Dry &Mill BlendC/T 1.2 sI2.10 d390-Station RotaryCompressionC/T 1.2 sI1.20 d4Aqueous Pan FilmCoatingC/T 1.2 sI1.40 d5Blister, Leaflet& Case PackC/T 1.2 sI1.80 dCUSTOMERRetail PharmacyWholesalers240,000 / units

Process steps

StepCycle timeChangeoverUptimeYieldBatchStock beforeCapacity per day
1. Weigh, Sieve & High-Shear Wet1.2 s45 min94%99.1%360,000384,000 (1.60 d)61,482
2. Fluid-Bed Dry & Mill Blend1.2 s75 min89%97.6%360,000432,000 (1.80 d)56,462
3. 90-Station Rotary Compression1.2 s65 min84%96.1%360,000504,000 (2.10 d)52,740
4. Aqueous Pan Film Coating1.2 s35 min91%98.2%192,000288,000 (1.20 d)58,365
5. Blister, Leaflet & Case Pack1.2 s15 min95%99.4%120,000336,000 (1.40 d)62,324

Key figures

Takt time
0.3 s
Lead time
9.90 d
Value-added time
6.0 s
Process cycle efficiency (PCE)
0.001%
Rolled throughput yield (RTY)
90.7%
Customer demand per day
240,000 units
Line capacity per day
52,740 units
Bottleneck
90-Station Rotary Compression

Reading the bottleneck

The bottleneck is "90-Station Rotary Compression": it can process 52,740 units per day against a demand of 240,000 units, so it falls short of demand by 78.0%. Once downtime and scrap are counted, its cycle time grows from 1.2 s to 1.5 s, against a takt of 0.3 s. The largest loss at this step is equipment downtime (uptime 84%), about 0.2 s per unit. Reducing that loss is where the first improvement test belongs.

The figures on this page are illustrative starting values to be replaced with your own measurements. They are not industry benchmarks.

Other scenarios in this family

More scenarios of Oral Solid Dose, Tablets & Blister: Oral Solid Dose, Tablets & Blister