Randomized Double-Blind Clinical Trial Kit Pack

Product family: Phase-III Placebo-Controlled Kits.

Flow: CRO Trial Sponsors → Randomization Label Print → Double-Blind Bottle Over-Encap → Tamper Wallet Blister Pack → Barcode Blind Check 100% → GDP Phase-III Depot Dispatch → Global Clinical Trial Sites

Open this map in the free editor

No account needed. Change any value and the indicators update.

Value stream map

Value stream map: Randomized Double-Blind Clinical Trial Kit PackSupplier on the left, customer on the right, process steps in between with their cycle time, and a stock triangle with days of stock before each step. CRO Trial Sponsors → Randomization Label Print (22.9 s) → Double-Blind Bottle Over-Encap (26.7 s) → Tamper Wallet Blister Pack (34.0 s) → Barcode Blind Check 100% (24.8 s) → GDP Phase-III Depot Dispatch (19.7 s) → Global Clinical Trial Sites.SUPPLIERCRO TrialSponsorsI1.60 d1RandomizationLabel PrintC/T 22.9 sI1.80 d2Double-BlindBottle Over-EncapC/T 26.7 sI2.10 d3Tamper WalletBlister PackC/T 34.0 sI1.20 d4Barcode BlindCheck 100%C/T 24.8 sI1.40 d5GDP Phase-IIIDepot DispatchC/T 19.7 sI1.80 dCUSTOMERGlobal ClinicalTrial Sites850 / packs

Process steps

StepCycle timeChangeoverUptimeYieldBatchStock beforeCapacity per day
1. Randomization Label Print22.9 s45 min94%99.1%1,2751,360 (1.60 d)1,025
2. Double-Blind Bottle Over-Encap26.7 s75 min89%97.6%1,2751,530 (1.80 d)781
3. Tamper Wallet Blister Pack34.0 s65 min84%96.1%1,2751,785 (2.10 d)579
4. Barcode Blind Check 100%24.8 s35 min91%98.2%6801,020 (1.20 d)878
5. GDP Phase-III Depot Dispatch19.7 s15 min95%99.4%4251,190 (1.40 d)1,208

Key figures

Takt time
31.8 s
Lead time
9.90 d
Value-added time
128 s
Process cycle efficiency (PCE)
0.048%
Rolled throughput yield (RTY)
90.7%
Customer demand per day
850 packs
Line capacity per day
579 packs
Bottleneck
Tamper Wallet Blister Pack

Reading the bottleneck

The bottleneck is "Tamper Wallet Blister Pack": it can process 579 packs per day against a demand of 850 packs, so it falls short of demand by 31.8%. Once downtime and scrap are counted, its cycle time grows from 34.0 s to 42.1 s, against a takt of 31.8 s. The largest loss at this step is equipment downtime (uptime 84%), about 6.5 s per unit. Reducing that loss is where the first improvement test belongs.

The figures on this page are illustrative starting values to be replaced with your own measurements. They are not industry benchmarks.

Other scenarios in this family

More scenarios of Oral Solid Dose, Tablets & Blister: Oral Solid Dose, Tablets & Blister