4-Lane Aluminum Foil Stick-Pack Powder Line

Product family: Oral Electrolytes & Probiotics.

Flow: Barrier Foil Supplier → V-Blender Homogeneous Mix → 4-Lane Servo Auger Stick Fill → Ultrasonic Tear-Notch Seal → Inline Weight & Leak Probe → Auto Stick Cartoner Box → OTC Consumer Health

Open this map in the free editor

No account needed. Change any value and the indicators update.

Value stream map

Value stream map: 4-Lane Aluminum Foil Stick-Pack Powder LineSupplier on the left, customer on the right, process steps in between with their cycle time, and a stock triangle with days of stock before each step. Barrier Foil Supplier → V-Blender Homogeneous Mix (1.2 s) → 4-Lane Servo Auger Stick Fill (1.2 s) → Ultrasonic Tear-Notch Seal (1.2 s) → Inline Weight & Leak Probe (1.2 s) → Auto Stick Cartoner Box (1.2 s) → OTC Consumer Health.SUPPLIERBarrier FoilSupplierI1.60 d1V-BlenderHomogeneous MixC/T 1.2 sI1.80 d24-Lane ServoAuger Stick FillC/T 1.2 sI2.10 d3UltrasonicTear-Notch SealC/T 1.2 sI1.20 d4Inline Weight &Leak ProbeC/T 1.2 sI1.40 d5Auto StickCartoner BoxC/T 1.2 sI1.80 dCUSTOMEROTC ConsumerHealth95,000 / packs

Process steps

StepCycle timeChangeoverUptimeYieldBatchStock beforeCapacity per day
1. V-Blender Homogeneous Mix1.2 s45 min94%99.1%142,500152,000 (1.60 d)40,522
2. 4-Lane Servo Auger Stick Fill1.2 s75 min89%97.6%142,500171,000 (1.80 d)36,917
3. Ultrasonic Tear-Notch Seal1.2 s65 min84%96.1%142,500199,500 (2.10 d)34,577
4. Inline Weight & Leak Probe1.2 s35 min91%98.2%76,000114,000 (1.20 d)38,258
5. Auto Stick Cartoner Box1.2 s15 min95%99.4%47,500133,000 (1.40 d)41,077

Key figures

Takt time
0.6 s
Lead time
9.90 d
Value-added time
6.0 s
Process cycle efficiency (PCE)
0.001%
Rolled throughput yield (RTY)
90.7%
Customer demand per day
95,000 packs
Line capacity per day
34,577 packs
Bottleneck
Ultrasonic Tear-Notch Seal

Reading the bottleneck

The bottleneck is "Ultrasonic Tear-Notch Seal": it can process 34,577 packs per day against a demand of 95,000 packs, so it falls short of demand by 63.6%. Once downtime and scrap are counted, its cycle time grows from 1.2 s to 1.5 s, against a takt of 0.6 s. The largest loss at this step is equipment downtime (uptime 84%), about 0.2 s per unit. Reducing that loss is where the first improvement test belongs.

The figures on this page are illustrative starting values to be replaced with your own measurements. They are not industry benchmarks.

Other scenarios in this family

More scenarios of Oral Solid Dose, Tablets & Blister: Oral Solid Dose, Tablets & Blister