Rotary Die Liquid-Fill Softgel Vitamin Line

Product family: Omega-3 & Fat-Soluble Softgels.

Flow: Halal Gelatin Supplier → Gelatin Melt & De-Aerate Tank → Water-Cooled Rotary Die Encap → Tumble & 36h Tunnel Drying → Optical Laser Sizing & Sort → HDPE Bulk Barrel / Bottle → Nutra & Pharma Retailers

Open this map in the free editor

No account needed. Change any value and the indicators update.

Value stream map

Value stream map: Rotary Die Liquid-Fill Softgel Vitamin LineSupplier on the left, customer on the right, process steps in between with their cycle time, and a stock triangle with days of stock before each step. Halal Gelatin Supplier → Gelatin Melt & De-Aerate Tank (1.2 s) → Water-Cooled Rotary Die Encap (1.2 s) → Tumble & 36h Tunnel Drying (1.2 s) → Optical Laser Sizing & Sort (1.2 s) → HDPE Bulk Barrel / Bottle (1.2 s) → Nutra & Pharma Retailers.SUPPLIERHalal GelatinSupplierI1.60 d1Gelatin Melt &De-Aerate TankC/T 1.2 sI1.80 d2Water-CooledRotary Die EncapC/T 1.2 sI2.10 d3Tumble & 36hTunnel DryingC/T 1.2 sI1.20 d4Optical LaserSizing & SortC/T 1.2 sI1.40 d5HDPE Bulk Barrel/ BottleC/T 1.2 sI1.80 dCUSTOMERNutra & PharmaRetailers210,000 / units

Process steps

StepCycle timeChangeoverUptimeYieldBatchStock beforeCapacity per day
1. Gelatin Melt & De-Aerate Tank1.2 s45 min94%99.1%315,000336,000 (1.60 d)61,482
2. Water-Cooled Rotary Die Encap1.2 s75 min89%97.6%315,000378,000 (1.80 d)56,462
3. Tumble & 36h Tunnel Drying1.2 s65 min84%96.1%315,000441,000 (2.10 d)52,740
4. Optical Laser Sizing & Sort1.2 s35 min91%98.2%168,000252,000 (1.20 d)58,365
5. HDPE Bulk Barrel / Bottle1.2 s15 min95%99.4%105,000294,000 (1.40 d)62,324

Key figures

Takt time
0.4 s
Lead time
9.90 d
Value-added time
6.0 s
Process cycle efficiency (PCE)
0.001%
Rolled throughput yield (RTY)
90.7%
Customer demand per day
210,000 units
Line capacity per day
52,740 units
Bottleneck
Tumble & 36h Tunnel Drying

Reading the bottleneck

The bottleneck is "Tumble & 36h Tunnel Drying": it can process 52,740 units per day against a demand of 210,000 units, so it falls short of demand by 74.9%. Once downtime and scrap are counted, its cycle time grows from 1.2 s to 1.5 s, against a takt of 0.4 s. The largest loss at this step is equipment downtime (uptime 84%), about 0.2 s per unit. Reducing that loss is where the first improvement test belongs.

The figures on this page are illustrative starting values to be replaced with your own measurements. They are not industry benchmarks.

Other scenarios in this family

More scenarios of Oral Solid Dose, Tablets & Blister: Oral Solid Dose, Tablets & Blister