Hardware-in-Loop (HIL) Embedded Firmware Rig

Product family: Nightly Automated Firmware Regress.

Flow: HIL Test Rig Crates → Automated Binary Target Flash → Simulated Sensor Fault Inject → CAN/LIN Bus Timing Capture → Coverage & Anomaly Alert Fix → Signed Release Candidate Tag → Firmware Control Teams

Open this map in the free editor

No account needed. Change any value and the indicators update.

Value stream map

Value stream map: Hardware-in-Loop (HIL) Embedded Firmware RigSupplier on the left, customer on the right, process steps in between with their cycle time, and a stock triangle with days of stock before each step. HIL Test Rig Crates → Automated Binary Target Flash (1,296 s) → Simulated Sensor Fault Inject (1,512 s) → CAN/LIN Bus Timing Capture (1,944 s) → Coverage & Anomaly Alert Fix (1,368 s) → Signed Release Candidate Tag (1,008 s) → Firmware Control Teams.SUPPLIERHIL Test RigCratesI2.00 d1Automated BinaryTarget FlashC/T 1,296 sI1.80 d2Simulated SensorFault InjectC/T 1,512 sI3.00 d3CAN/LIN BusTiming CaptureC/T 1,944 sI1.20 d4Coverage &Anomaly Alert FixC/T 1,368 sI0.70 d5Signed ReleaseCandidate TagC/T 1,008 sI1.00 dCUSTOMERFirmwareControl Teams30 / batches

Process steps

StepCycle timeChangeoverUptimeYieldBatchStock beforeCapacity per day
1. Automated Binary Target Flash1,296 s20 min94%96.5%2460 (2.00 d)37
2. Simulated Sensor Fault Inject1,512 s15 min91%93.8%1554 (1.80 d)29
3. CAN/LIN Bus Timing Capture1,944 s35 min83%89.5%2490 (3.00 d)20
4. Coverage & Anomaly Alert Fix1,368 s12 min94%97.6%1236 (1.20 d)35
5. Signed Release Candidate Tag1,008 s5 min98%99.1%621 (0.70 d)51

Key figures

Takt time
1,800 s
Lead time
9.83 d
Value-added time
7,128 s
Process cycle efficiency (PCE)
1.3%
Rolled throughput yield (RTY)
78.4%
Customer demand per day
30 batches
Line capacity per day
20 batches
Bottleneck
CAN/LIN Bus Timing Capture

Reading the bottleneck

The bottleneck is "CAN/LIN Bus Timing Capture": it can process 20 batches per day against a demand of 30 batches, so it falls short of demand by 34.6%. Once downtime and scrap are counted, its cycle time grows from 1,944 s to 2,617 s, against a takt of 1,800 s. The largest loss at this step is equipment downtime (uptime 83%), about 398 s per unit. Reducing that loss is where the first improvement test belongs.

The figures on this page are illustrative starting values to be replaced with your own measurements. They are not industry benchmarks.

Other scenarios in this family

More scenarios of Hardware R&D, Prototyping & Compliance: Hardware R&D, Prototyping & Compliance