Thermal Dissipation Vapor-Chamber Wind Tunnel

Product family: IR Thermal Margin Sign-Off.

Flow: Macro IR & Airflow Rig → Thermocouple Matrix Epoxied → Closed-Loop Airflow Sweep → IR Radiometric Map Capture → TIM Paste Thickness Iterate → Throttle Margin Sign-Off → Server & Laptop R&D

Open this map in the free editor

No account needed. Change any value and the indicators update.

Value stream map

Value stream map: Thermal Dissipation Vapor-Chamber Wind TunnelSupplier on the left, customer on the right, process steps in between with their cycle time, and a stock triangle with days of stock before each step. Macro IR & Airflow Rig → Thermocouple Matrix Epoxied (1,215 s) → Closed-Loop Airflow Sweep (1,418 s) → IR Radiometric Map Capture (1,823 s) → TIM Paste Thickness Iterate (1,283 s) → Throttle Margin Sign-Off (945 s) → Server & Laptop R&D.SUPPLIERMacro IR &Airflow RigI2.00 d1ThermocoupleMatrix EpoxiedC/T 1,215 sI1.81 d2Closed-LoopAirflow SweepC/T 1,418 sI3.00 d3IR RadiometricMap CaptureC/T 1,823 sI1.19 d4TIM PasteThickness IterateC/T 1,283 sI0.69 d5Throttle MarginSign-OffC/T 945 sI1.00 dCUSTOMERServer & LaptopR&D16 / cases

Process steps

StepCycle timeChangeoverUptimeYieldBatchStock beforeCapacity per day
1. Thermocouple Matrix Epoxied1,215 s20 min94%96.5%1332 (2.00 d)19
2. Closed-Loop Airflow Sweep1,418 s15 min91%93.8%829 (1.81 d)15
3. IR Radiometric Map Capture1,823 s35 min83%89.5%1348 (3.00 d)10
4. TIM Paste Thickness Iterate1,283 s12 min94%97.6%619 (1.19 d)18
5. Throttle Margin Sign-Off945 s5 min98%99.1%311 (0.69 d)26

Key figures

Takt time
1,688 s
Lead time
9.94 d
Value-added time
6,684 s
Process cycle efficiency (PCE)
2.5%
Rolled throughput yield (RTY)
78.4%
Customer demand per day
16 cases
Line capacity per day
10 cases
Bottleneck
IR Radiometric Map Capture

Reading the bottleneck

The bottleneck is "IR Radiometric Map Capture": it can process 10 cases per day against a demand of 16 cases, so it falls short of demand by 37.8%. Once downtime and scrap are counted, its cycle time grows from 1,823 s to 2,454 s, against a takt of 1,688 s. The largest loss at this step is equipment downtime (uptime 83%), about 373 s per unit. Reducing that loss is where the first improvement test belongs.

The figures on this page are illustrative starting values to be replaced with your own measurements. They are not industry benchmarks.

Other scenarios in this family

More scenarios of Hardware R&D, Prototyping & Compliance: Hardware R&D, Prototyping & Compliance