Custom AR/VR Pancake Lens Optical Alignment

Product family: Waveguide MTF Calibration.

Flow: Optical Alignment System → Clean Mount Micro-Display Jig → 6-Axis Tilt & Focus Scan → Ghosting & Stray Light Check → Binocular Vergence Match → Master Jig Tolerance Lock → XR Headset R&D Labs

Open this map in the free editor

No account needed. Change any value and the indicators update.

Value stream map

Value stream map: Custom AR/VR Pancake Lens Optical AlignmentSupplier on the left, customer on the right, process steps in between with their cycle time, and a stock triangle with days of stock before each step. Optical Alignment System → Clean Mount Micro-Display Jig (1,080 s) → 6-Axis Tilt & Focus Scan (1,260 s) → Ghosting & Stray Light Check (1,620 s) → Binocular Vergence Match (1,140 s) → Master Jig Tolerance Lock (840 s) → XR Headset R&D Labs.SUPPLIEROpticalAlignmentSystemI2.00 d1Clean MountMicro-Display JigC/T 1,080 sI1.78 d26-Axis Tilt &Focus ScanC/T 1,260 sI3.00 d3Ghosting & StrayLight CheckC/T 1,620 sI1.22 d4BinocularVergence MatchC/T 1,140 sI0.72 d5Master JigTolerance LockC/T 840 sI1.00 dCUSTOMERXR Headset R&DLabs18 / cases

Process steps

StepCycle timeChangeoverUptimeYieldBatchStock beforeCapacity per day
1. Clean Mount Micro-Display Jig1,080 s20 min94%96.5%1436 (2.00 d)21
2. 6-Axis Tilt & Focus Scan1,260 s15 min91%93.8%932 (1.78 d)17
3. Ghosting & Stray Light Check1,620 s35 min83%89.5%1454 (3.00 d)11
4. Binocular Vergence Match1,140 s12 min94%97.6%722 (1.22 d)20
5. Master Jig Tolerance Lock840 s5 min98%99.1%413 (0.72 d)30

Key figures

Takt time
1,500 s
Lead time
9.94 d
Value-added time
5,940 s
Process cycle efficiency (PCE)
2.2%
Rolled throughput yield (RTY)
78.4%
Customer demand per day
18 cases
Line capacity per day
11 cases
Bottleneck
Ghosting & Stray Light Check

Reading the bottleneck

The bottleneck is "Ghosting & Stray Light Check": it can process 11 cases per day against a demand of 18 cases, so it falls short of demand by 38.1%. Once downtime and scrap are counted, its cycle time grows from 1,620 s to 2,181 s, against a takt of 1,500 s. The largest loss at this step is equipment downtime (uptime 83%), about 332 s per unit. Reducing that loss is where the first improvement test belongs.

The figures on this page are illustrative starting values to be replaced with your own measurements. They are not industry benchmarks.

Other scenarios in this family

More scenarios of Hardware R&D, Prototyping & Compliance: Hardware R&D, Prototyping & Compliance