42-Meter Hollow Marine Propulsion Shaft Line

Product family: Forged Duplex Stainless Shafts.

Flow: Steel forging house → Deep Trepanning Bore 18m → CNC Turning Steady Rest → GRP Composite Protective Wrap → Ultrasonic Concentricity Check → Class-Society Sea Stamp → Frigate Shipyard Slipway

Open this map in the free editor

No account needed. Change any value and the indicators update.

Value stream map

Value stream map: 42-Meter Hollow Marine Propulsion Shaft LineSupplier on the left, customer on the right, process steps in between with their cycle time, and a stock triangle with days of stock before each step. Steel forging house → Deep Trepanning Bore 18m (9,180 s) → CNC Turning Steady Rest (11,340 s) → GRP Composite Protective Wrap (14,445 s) → Ultrasonic Concentricity Check (10,530 s) → Class-Society Sea Stamp (7,830 s) → Frigate Shipyard Slipway.SUPPLIERSteel forginghouseI2.00 d1Deep TrepanningBore 18mC/T 9,180 sI1.75 d2CNC TurningSteady RestC/T 11,340 sI2.50 d3GRP CompositeProtective WrapC/T 14,445 sI1.50 d4UltrasonicConcentricity…C/T 10,530 sI0.75 d5Class-Society SeaStampC/T 7,830 sI1.50 dCUSTOMERFrigateShipyard…4 / parts

Process steps

StepCycle timeChangeoverUptimeYieldBatchStock beforeCapacity per day
1. Deep Trepanning Bore 18m9,180 s35 min95%99.0%68 (2.00 d)5
2. CNC Turning Steady Rest11,340 s30 min91%96.5%37 (1.75 d)4
3. GRP Composite Protective Wrap14,445 s45 min84%94.8%410 (2.50 d)3
4. Ultrasonic Concentricity Check10,530 s25 min92%97.6%36 (1.50 d)4
5. Class-Society Sea Stamp7,830 s10 min97%99.2%13 (0.75 d)7

Key figures

Takt time
13,500 s
Lead time
11.0 d
Value-added time
53,325 s
Process cycle efficiency (PCE)
9.0%
Rolled throughput yield (RTY)
87.7%
Customer demand per day
4 parts
Line capacity per day
3 parts
Bottleneck
GRP Composite Protective Wrap

Reading the bottleneck

The bottleneck is "GRP Composite Protective Wrap": it can process 3 parts per day against a demand of 4 parts, so it falls short of demand by 29.3%. Once downtime and scrap are counted, its cycle time grows from 14,445 s to 18,140 s, against a takt of 13,500 s. The largest loss at this step is equipment downtime (uptime 84%), about 2,751 s per unit. Reducing that loss is where the first improvement test belongs.

The figures on this page are illustrative starting values to be replaced with your own measurements. They are not industry benchmarks.

Other scenarios in this family

More scenarios of Defense, Naval & Optronics Systems: Defense, Naval & Optronics Systems