Box-Fermented Traceable Fine-Flavor Cocoa Bean

Product family: 7-Day Turned Cocoa Lots.

Flow: Certified Forest Farms → Pod Break & Cascading Boxes → 48h Aerobic Turn & Temp Log → Solar Tunnel Dry to 7% Moist → Cut-Test Fermentation Assay → EUDR GPS-Tagged Jute Lot → European Chocolate Makers

Open this map in the free editor

No account needed. Change any value and the indicators update.

Value stream map

Value stream map: Box-Fermented Traceable Fine-Flavor Cocoa BeanSupplier on the left, customer on the right, process steps in between with their cycle time, and a stock triangle with days of stock before each step. Certified Forest Farms → Pod Break & Cascading Boxes (1,080 s) → 48h Aerobic Turn & Temp Log (1,334 s) → Solar Tunnel Dry to 7% Moist (1,699 s) → Cut-Test Fermentation Assay (1,175 s) → EUDR GPS-Tagged Jute Lot (889 s) → European Chocolate Makers.SUPPLIERCertifiedForest FarmsI0.91 d1Pod Break &Cascading BoxesC/T 1,080 sI1.50 d248h Aerobic Turn& Temp LogC/T 1,334 sI2.00 d3Solar Tunnel Dryto 7% MoistC/T 1,699 sI1.09 d4Cut-TestFermentation…C/T 1,175 sI1.00 d5EUDR GPS-TaggedJute LotC/T 889 sI1.50 dCUSTOMEREuropeanChocolate…34 / tonnes

Process steps

StepCycle timeChangeoverUptimeYieldBatchStock beforeCapacity per day
1. Pod Break & Cascading Boxes1,080 s12 min94%98.2%1731 (0.91 d)45
2. 48h Aerobic Turn & Temp Log1,334 s20 min91%97.1%2051 (1.50 d)34
3. Solar Tunnel Dry to 7% Moist1,699 s35 min84%95.5%2768 (2.00 d)24
4. Cut-Test Fermentation Assay1,175 s15 min93%98.1%1437 (1.09 d)40
5. EUDR GPS-Tagged Jute Lot889 s10 min97%99.3%1034 (1.00 d)56

Key figures

Takt time
1,588 s
Lead time
8.11 d
Value-added time
6,177 s
Process cycle efficiency (PCE)
1.4%
Rolled throughput yield (RTY)
88.7%
Customer demand per day
34 tonnes
Line capacity per day
24 tonnes
Bottleneck
Solar Tunnel Dry to 7% Moist

Reading the bottleneck

The bottleneck is "Solar Tunnel Dry to 7% Moist": it can process 24 tonnes per day against a demand of 34 tonnes, so it falls short of demand by 28.7%. Once downtime and scrap are counted, its cycle time grows from 1,699 s to 2,118 s, against a takt of 1,588 s. The largest loss at this step is equipment downtime (uptime 84%), about 324 s per unit. Reducing that loss is where the first improvement test belongs.

The figures on this page are illustrative starting values to be replaced with your own measurements. They are not industry benchmarks.

Other scenarios in this family

More scenarios of Commodities, Coffee, Cocoa & Forestry: Commodities, Coffee, Cocoa & Forestry