VNT Remanufactured Passenger Turbocharger

Product family: Balanced CHRA Core Cartridges.

Flow: IAM Core Logistics → Turbine Hot-Side Blasting → Precision Shaft Journal Polish → New Bearing & Seal Fit → High-Speed VSR Balancer → Flow-Bench Actuator Set → Regional parts warehouses

Open this map in the free editor

No account needed. Change any value and the indicators update.

Value stream map

Value stream map: VNT Remanufactured Passenger TurbochargerSupplier on the left, customer on the right, process steps in between with their cycle time, and a stock triangle with days of stock before each step. IAM Core Logistics → Turbine Hot-Side Blasting (81.0 s) → Precision Shaft Journal Polish (88.0 s) → New Bearing & Seal Fit (122 s) → High-Speed VSR Balancer (83.0 s) → Flow-Bench Actuator Set (63.0 s) → Regional parts warehouses.SUPPLIERIAM CoreLogisticsI2.40 d1Turbine Hot-SideBlastingC/T 81.0 sI1.80 d2Precision ShaftJournal PolishC/T 88.0 sI2.10 d3New Bearing &Seal FitC/T 122 sI1.00 d4High-Speed VSRBalancerC/T 83.0 sI0.90 d5Flow-BenchActuator SetC/T 63.0 sI2.20 dCUSTOMERRegional partswarehouses480 / units

Process steps

StepCycle timeChangeoverUptimeYieldBatchStock beforeCapacity per day
1. Turbine Hot-Side Blasting81.0 s15 min94%92.5%4801,152 (2.40 d)570
2. Precision Shaft Journal Polish88.0 s20 min92%97.6%480864 (1.80 d)539
3. New Bearing & Seal Fit122 s30 min85%94.2%3841,008 (2.10 d)340
4. High-Speed VSR Balancer83.0 s12 min94%98.4%192480 (1.00 d)582
5. Flow-Bench Actuator Set63.0 s8 min97%99.4%240432 (0.90 d)812

Key figures

Takt time
113 s
Lead time
10.4 d
Value-added time
437 s
Process cycle efficiency (PCE)
0.078%
Rolled throughput yield (RTY)
83.2%
Customer demand per day
480 units
Line capacity per day
340 units
Bottleneck
New Bearing & Seal Fit

Reading the bottleneck

The bottleneck is "New Bearing & Seal Fit": it can process 340 units per day against a demand of 480 units, so it falls short of demand by 29.2%. Once downtime and scrap are counted, its cycle time grows from 122 s to 152 s, against a takt of 113 s. The largest loss at this step is equipment downtime (uptime 85%), about 21.5 s per unit. Reducing that loss is where the first improvement test belongs.

The figures on this page are illustrative starting values to be replaced with your own measurements. They are not industry benchmarks.

Other scenarios in this family

More scenarios of Aftermarket & Remanufacturing: Aftermarket & Remanufacturing