Balanced Cantilever Cast-in-Situ Bridge Span

Product family: Post-Tension Box Girders.

Flow: Travelers & Strand Jacks → Form-Traveler Advance & Pin → Box-Girder Rebar & Tendon Duct → Balanced Symmetric Concrete → Hydraulic Stressing & Grouting → Camber Elevation Laser Audit → River & Viaduct Crossings

Open this map in the free editor

No account needed. Change any value and the indicators update.

Value stream map

Value stream map: Balanced Cantilever Cast-in-Situ Bridge SpanSupplier on the left, customer on the right, process steps in between with their cycle time, and a stock triangle with days of stock before each step. Travelers & Strand Jacks → Form-Traveler Advance & Pin (6,120 s) → Box-Girder Rebar & Tendon Duct (7,560 s) → Balanced Symmetric Concrete (9,720 s) → Hydraulic Stressing & Grouting (7,020 s) → Camber Elevation Laser Audit (5,040 s) → River & Viaduct Crossings.SUPPLIERTravelers &Strand JacksI1.50 d1Form-TravelerAdvance & PinC/T 6,120 sI1.83 d2Box-Girder Rebar& Tendon DuctC/T 7,560 sI2.17 d3BalancedSymmetric…C/T 9,720 sI1.67 d4HydraulicStressing &…C/T 7,020 sI0.83 d5Camber ElevationLaser AuditC/T 5,040 sI0.67 dCUSTOMERRiver & ViaductCrossings6 / cases

Process steps

StepCycle timeChangeoverUptimeYieldBatchStock beforeCapacity per day
1. Form-Traveler Advance & Pin6,120 s25 min94%97.6%59 (1.50 d)8
2. Box-Girder Rebar & Tendon Duct7,560 s30 min91%96.5%411 (1.83 d)6
3. Balanced Symmetric Concrete9,720 s40 min84%94.8%313 (2.17 d)4
4. Hydraulic Stressing & Grouting7,020 s20 min93%98.0%310 (1.67 d)7
5. Camber Elevation Laser Audit5,040 s10 min97%99.1%25 (0.83 d)10

Key figures

Takt time
9,000 s
Lead time
9.32 d
Value-added time
35,460 s
Process cycle efficiency (PCE)
7.0%
Rolled throughput yield (RTY)
86.7%
Customer demand per day
6 cases
Line capacity per day
4 cases
Bottleneck
Balanced Symmetric Concrete

Reading the bottleneck

The bottleneck is "Balanced Symmetric Concrete": it can process 4 cases per day against a demand of 6 cases, so it falls short of demand by 32.8%. Once downtime and scrap are counted, its cycle time grows from 9,720 s to 12,206 s, against a takt of 9,000 s. The largest loss at this step is equipment downtime (uptime 84%), about 1,851 s per unit. Reducing that loss is where the first improvement test belongs.

The figures on this page are illustrative starting values to be replaced with your own measurements. They are not industry benchmarks.

Other scenarios in this family

More scenarios of Civil Engineering, Bridges, Tunnels & Rail: Civil Engineering, Bridges, Tunnels & Rail