GPS Machine-Guided Highway Cut-and-Fill Haul

Product family: Balanced Mass-Haul Earthworks.

Flow: Borrow Pit & Quarry Cuts → 3D Drone Cut/Fill Volume Map → GPS Dozer & Excavator Load → Articulated Dump Truck Cycle → Vibratory Padfoot Compaction → Plate Load Ev2 Bearing Cert → Motorway & Rail Subgrades

Open this map in the free editor

No account needed. Change any value and the indicators update.

Value stream map

Value stream map: GPS Machine-Guided Highway Cut-and-Fill HaulSupplier on the left, customer on the right, process steps in between with their cycle time, and a stock triangle with days of stock before each step. Borrow Pit & Quarry Cuts → 3D Drone Cut/Fill Volume Map (115 s) → GPS Dozer & Excavator Load (142 s) → Articulated Dump Truck Cycle (182 s) → Vibratory Padfoot Compaction (132 s) → Plate Load Ev2 Bearing Cert (95.0 s) → Motorway & Rail Subgrades.SUPPLIERBorrow Pit &Quarry CutsI1.50 d13D Drone Cut/FillVolume MapC/T 115 sI1.80 d2GPS Dozer &Excavator LoadC/T 142 sI2.20 d3Articulated DumpTruck CycleC/T 182 sI1.60 d4Vibratory PadfootCompactionC/T 132 sI0.80 d5Plate Load Ev2Bearing CertC/T 95.0 sI0.60 dCUSTOMERMotorway & RailSubgrades320 / batches

Process steps

StepCycle timeChangeoverUptimeYieldBatchStock beforeCapacity per day
1. 3D Drone Cut/Fill Volume Map115 s25 min94%97.6%256480 (1.50 d)416
2. GPS Dozer & Excavator Load142 s30 min91%96.5%192576 (1.80 d)315
3. Articulated Dump Truck Cycle182 s40 min84%94.8%160704 (2.20 d)215
4. Vibratory Padfoot Compaction132 s20 min93%98.0%160512 (1.60 d)356
5. Plate Load Ev2 Bearing Cert95.0 s10 min97%99.1%96256 (0.80 d)526

Key figures

Takt time
169 s
Lead time
8.51 d
Value-added time
666 s
Process cycle efficiency (PCE)
0.14%
Rolled throughput yield (RTY)
86.7%
Customer demand per day
320 batches
Line capacity per day
215 batches
Bottleneck
Articulated Dump Truck Cycle

Reading the bottleneck

The bottleneck is "Articulated Dump Truck Cycle": it can process 215 batches per day against a demand of 320 batches, so it falls short of demand by 32.7%. Once downtime and scrap are counted, its cycle time grows from 182 s to 229 s, against a takt of 169 s. The largest loss at this step is equipment downtime (uptime 84%), about 34.7 s per unit. Reducing that loss is where the first improvement test belongs.

The figures on this page are illustrative starting values to be replaced with your own measurements. They are not industry benchmarks.

Other scenarios in this family

More scenarios of Civil Engineering, Bridges, Tunnels & Rail: Civil Engineering, Bridges, Tunnels & Rail