Red-Bag Hospital Bio-Waste Autoclave Shred Line

Product family: Zero-Pathogen Hospital Disposal.

Flow: Regional Clinics & Hospitals → Barcode Bin Manifest Weigh → Pre-Shred Vacuum Steam Chamber → 138°C 40-Min Pathogen Hold → Dewater Compaction Extrude → Daily Geobacillus Spore QC → Municipal Clean Landfill

Open this map in the free editor

No account needed. Change any value and the indicators update.

Value stream map

Value stream map: Red-Bag Hospital Bio-Waste Autoclave Shred LineSupplier on the left, customer on the right, process steps in between with their cycle time, and a stock triangle with days of stock before each step. Regional Clinics & Hospitals → Barcode Bin Manifest Weigh (720 s) → Pre-Shred Vacuum Steam Chamber (900 s) → 138°C 40-Min Pathogen Hold (1,204 s) → Dewater Compaction Extrude (810 s) → Daily Geobacillus Spore QC (608 s) → Municipal Clean Landfill.SUPPLIERRegionalClinics &HospitalsI1.21 d1Barcode BinManifest WeighC/T 720 sI1.29 d2Pre-Shred VacuumSteam ChamberC/T 900 sI1.79 d3138°C 40-MinPathogen HoldC/T 1,204 sI0.90 d4DewaterCompaction…C/T 810 sI0.60 d5Daily GeobacillusSpore QCC/T 608 sI1.00 dCUSTOMERMunicipal CleanLandfill48 / tonnes

Process steps

StepCycle timeChangeoverUptimeYieldBatchStock beforeCapacity per day
1. Barcode Bin Manifest Weigh720 s15 min95%98.5%3858 (1.21 d)69
2. Pre-Shred Vacuum Steam Chamber900 s20 min92%97.4%2962 (1.29 d)52
3. 138°C 40-Min Pathogen Hold1,204 s30 min84%95.8%3886 (1.79 d)35
4. Dewater Compaction Extrude810 s10 min95%98.8%1943 (0.90 d)61
5. Daily Geobacillus Spore QC608 s8 min97%99.4%1229 (0.60 d)83

Key figures

Takt time
1,125 s
Lead time
6.87 d
Value-added time
4,242 s
Process cycle efficiency (PCE)
1.1%
Rolled throughput yield (RTY)
90.3%
Customer demand per day
48 tonnes
Line capacity per day
35 tonnes
Bottleneck
138°C 40-Min Pathogen Hold

Reading the bottleneck

The bottleneck is "138°C 40-Min Pathogen Hold": it can process 35 tonnes per day against a demand of 48 tonnes, so it falls short of demand by 28.0%. Once downtime and scrap are counted, its cycle time grows from 1,204 s to 1,496 s, against a takt of 1,125 s. The largest loss at this step is equipment downtime (uptime 84%), about 229 s per unit. Reducing that loss is where the first improvement test belongs.

The figures on this page are illustrative starting values to be replaced with your own measurements. They are not industry benchmarks.

Other scenarios in this family

More scenarios of Water Desalination, Waste & Recycling MRF: Water Desalination, Waste & Recycling MRF