1150°C Rotary Kiln Hazardous Chemical Destruction

Product family: 99.9999% DRE Incineration.

Flow: Solvent Drums & Pharma Waste → Lab Fingerprinting & Blend → Drum Shredder & Lance Atomize → 1150°C Rotary Kiln & 2s After → Quench, Baghouse & Wet Scrub → CEMS Continuous Emission Out → Industrial Waste District Heat

Open this map in the free editor

No account needed. Change any value and the indicators update.

Value stream map

Value stream map: 1150°C Rotary Kiln Hazardous Chemical DestructionSupplier on the left, customer on the right, process steps in between with their cycle time, and a stock triangle with days of stock before each step. Solvent Drums & Pharma Waste → Lab Fingerprinting & Blend (576 s) → Drum Shredder & Lance Atomize (720 s) → 1150°C Rotary Kiln & 2s After (963 s) → Quench, Baghouse & Wet Scrub (648 s) → CEMS Continuous Emission Out (486 s) → Industrial Waste District Heat.SUPPLIERSolvent Drums &Pharma WasteI1.20 d1LabFingerprinting &…C/T 576 sI1.30 d2Drum Shredder &Lance AtomizeC/T 720 sI1.80 d31150°C RotaryKiln & 2s AfterC/T 963 sI0.90 d4Quench, Baghouse& Wet ScrubC/T 648 sI0.60 d5CEMS ContinuousEmission OutC/T 486 sI1.00 dCUSTOMERIndustrialWaste District…90 / tonnes

Process steps

StepCycle timeChangeoverUptimeYieldBatchStock beforeCapacity per day
1. Lab Fingerprinting & Blend576 s15 min95%98.5%72108 (1.20 d)130
2. Drum Shredder & Lance Atomize720 s20 min92%97.4%54117 (1.30 d)98
3. 1150°C Rotary Kiln & 2s After963 s30 min84%95.8%72162 (1.80 d)66
4. Quench, Baghouse & Wet Scrub648 s10 min95%98.8%3681 (0.90 d)115
5. CEMS Continuous Emission Out486 s8 min97%99.4%2354 (0.60 d)157

Key figures

Takt time
900 s
Lead time
6.84 d
Value-added time
3,393 s
Process cycle efficiency (PCE)
0.61%
Rolled throughput yield (RTY)
90.3%
Customer demand per day
90 tonnes
Line capacity per day
66 tonnes
Bottleneck
1150°C Rotary Kiln & 2s After

Reading the bottleneck

The bottleneck is "1150°C Rotary Kiln & 2s After": it can process 66 tonnes per day against a demand of 90 tonnes, so it falls short of demand by 26.9%. Once downtime and scrap are counted, its cycle time grows from 963 s to 1,197 s, against a takt of 900 s. The largest loss at this step is equipment downtime (uptime 84%), about 183 s per unit. Reducing that loss is where the first improvement test belongs.

The figures on this page are illustrative starting values to be replaced with your own measurements. They are not industry benchmarks.

Other scenarios in this family

More scenarios of Water Desalination, Waste & Recycling MRF: Water Desalination, Waste & Recycling MRF