4-High Cold Steel Rolling Mill Housing Stand

Product family: 80-Ton Cast Rolling Mill Frames.

Flow: Heavy Cast Steel Works → Cast Window UT & Stress Rel → Giant Horizontal Plane-Mill → Chock Window Liner Slide Fit → AGC Hydraulic Screwdown Pack → Zero-Deflection Frame Measure → Flat Steel Rollers

Open this map in the free editor

No account needed. Change any value and the indicators update.

Value stream map

Value stream map: 4-High Cold Steel Rolling Mill Housing StandSupplier on the left, customer on the right, process steps in between with their cycle time, and a stock triangle with days of stock before each step. Heavy Cast Steel Works → Cast Window UT & Stress Rel (9,180 s) → Giant Horizontal Plane-Mill (11,475 s) → Chock Window Liner Slide Fit (14,850 s) → AGC Hydraulic Screwdown Pack (11,070 s) → Zero-Deflection Frame Measure (8,640 s) → Flat Steel Rollers.SUPPLIERHeavy CastSteel WorksI2.00 d1Cast Window UT &Stress RelC/T 9,180 sI2.50 d2Giant HorizontalPlane-MillC/T 11,475 sI3.00 d3Chock WindowLiner Slide FitC/T 14,850 sI1.50 d4AGC HydraulicScrewdown PackC/T 11,070 sI1.00 d5Zero-DeflectionFrame MeasureC/T 8,640 sI1.50 dCUSTOMERFlat SteelRollers2 / units

Process steps

StepCycle timeChangeoverUptimeYieldBatchStock beforeCapacity per day
1. Cast Window UT & Stress Rel9,180 s30 min94%98.5%34 (2.00 d)3
2. Giant Horizontal Plane-Mill11,475 s45 min89%96.4%25 (2.50 d)2
3. Chock Window Liner Slide Fit14,850 s90 min83%95.8%26 (3.00 d)1
4. AGC Hydraulic Screwdown Pack11,070 s20 min92%97.4%13 (1.50 d)2
5. Zero-Deflection Frame Measure8,640 s15 min95%98.9%12 (1.00 d)3

Key figures

Takt time
13,500 s
Lead time
13.5 d
Value-added time
55,215 s
Process cycle efficiency (PCE)
15.1%
Rolled throughput yield (RTY)
87.6%
Customer demand per day
2 units
Line capacity per day
1 units
Bottleneck
Chock Window Liner Slide Fit

Reading the bottleneck

The bottleneck is "Chock Window Liner Slide Fit": it can process 1 units per day against a demand of 2 units, so it falls short of demand by 42.2%. Once downtime and scrap are counted, its cycle time grows from 14,850 s to 18,676 s, against a takt of 13,500 s. The largest loss at this step is equipment downtime (uptime 83%), about 3,042 s per unit. Reducing that loss is where the first improvement test belongs.

The figures on this page are illustrative starting values to be replaced with your own measurements. They are not industry benchmarks.

Other scenarios in this family

More scenarios of Industrial & Heavy Equipment OEMs: Industrial & Heavy Equipment OEMs