Ka-Band LEO Satellite Payload Transponder

Product family: Radiation-Hardened RF Transponders.

Flow: Rad-hard RF supplier → Gold-Plated Fe-Ni-Co Alloy Micro-Mach → Chip-and-Wire Cleanroom → Laser Hermetic Lid Seal → 14-Day Thermal Vacuum Bake → PIM Intermod & Phase Noise → Spacecraft Integration Bay

Open this map in the free editor

No account needed. Change any value and the indicators update.

Value stream map

Value stream map: Ka-Band LEO Satellite Payload TransponderSupplier on the left, customer on the right, process steps in between with their cycle time, and a stock triangle with days of stock before each step. Rad-hard RF supplier → Gold-Plated Fe-Ni-Co Alloy Micro-Mach (1,215 s) → Chip-and-Wire Cleanroom (1,384 s) → Laser Hermetic Lid Seal (1,823 s) → 14-Day Thermal Vacuum Bake (1,181 s) → PIM Intermod & Phase Noise (1,080 s) → Spacecraft Integration Bay.SUPPLIERRad-hard RFsupplierI1.50 d1Gold-PlatedFe-Ni-Co Alloy…C/T 1,215 sI1.63 d2Chip-and-WireCleanroomC/T 1,384 sI2.38 d3Laser HermeticLid SealC/T 1,823 sI1.13 d414-Day ThermalVacuum BakeC/T 1,181 sI0.88 d5PIM Intermod &Phase NoiseC/T 1,080 sI1.50 dCUSTOMERSpacecraftIntegration Bay16 / units

Process steps

StepCycle timeChangeoverUptimeYieldBatchStock beforeCapacity per day
1. Gold-Plated Fe-Ni-Co Alloy Micro-Mach1,215 s35 min94%98.2%1324 (1.50 d)19
2. Chip-and-Wire Cleanroom1,384 s15 min92%96.8%826 (1.63 d)16
3. Laser Hermetic Lid Seal1,823 s45 min85%93.8%1638 (2.38 d)11
4. 14-Day Thermal Vacuum Bake1,181 s20 min95%98.5%618 (1.13 d)19
5. PIM Intermod & Phase Noise1,080 s12 min96%99.1%414 (0.88 d)21

Key figures

Takt time
1,688 s
Lead time
9.25 d
Value-added time
6,683 s
Process cycle efficiency (PCE)
2.7%
Rolled throughput yield (RTY)
87.0%
Customer demand per day
16 units
Line capacity per day
11 units
Bottleneck
Laser Hermetic Lid Seal

Reading the bottleneck

The bottleneck is "Laser Hermetic Lid Seal": it can process 11 units per day against a demand of 16 units, so it falls short of demand by 33.6%. Once downtime and scrap are counted, its cycle time grows from 1,823 s to 2,286 s, against a takt of 1,688 s. The largest loss at this step is equipment downtime (uptime 85%), about 322 s per unit. Reducing that loss is where the first improvement test belongs.

The figures on this page are illustrative starting values to be replaced with your own measurements. They are not industry benchmarks.

Other scenarios in this family

More scenarios of Avionics, Space & Flight Electronics: Avionics, Space & Flight Electronics